Dismantling the previous mechanism
On CR60/CR120/CU-LT(1s):
1. Unlock the motor by
interrupting the power supply.
2. Loosen the fixing screws of
the motor and remove the old
motor.
Mounting the new mechanism
On CR60/CR120/CU-LT(1s)
1. Put the new membrane in place.
2. Make sur the damper blade is
closed.
3. Fasten the ONE on the damper
with the supplied (2) M6 screws.
4. Connect the motor according to
the wiring diagram.
5. Test the functioning of the
motor.
6. Apply the label 'KIT' to the
motor
If the product is manipulated in any other way than described in this manual, Rf-Technologies
will decline any responsibility and the guarantee will immediately expire!
Actuator
On CR2/CU2(/B)/CU4/CU2-15:
1. Unlock the motor by
interrupting the power supply.
2. Loosen the fixing screws of
the motor and remove the old
motor.
On CR2/CU2(/B)/CU4/CU2-15
1. Make sure the damper blade
is closed and the motor is
unlocked.
2. Fasten the ONE on the damper
with the supplied (2) M6 screws.
3. Connect the motor according to
the wiring diagram.
4. Test the functioning of the
motor.
5. Apply the label 'KIT' to the
motor.