Schéma d'évacuation de l'unité verticale
view 1
Figure 3.1 c
* D = 15 mm
/H EDF GH UpFXSpUDWLRQ G¶HDX GH FRQGHQVDWLRQ GH O¶DLU H[WUDLW GH O¶XQLWp HVW GRWp G¶XQ FkEOH FKDXIIDQW DXWRQRPH
/H FkEOH FKDXIIDQW HVW DFWLYp HQ PRGH FKDXIIDJH XQLTXHPHQW /H VpSDUDWHXU G¶HDX GRLW rWUH LQVWDOOp '
Gaines
/¶DLU HQWUH GDQV O¶XQLWp GH WUDLWHPHQW G¶DLU HW HQ VRUW YLD GHV JDLQHV ,O HVW UHFRPPDQGp G¶XWLOLVHU GHV JDLQHV HQ
DFLHU JDOYDQLVp =Q  JP
V\VWqPH GH JDLQHV DYHF XQ GpELW G¶DLU HW XQH SHUWH GH SUHVVLRQ IDLEOHV D¿Q G¶REWHQLU OH YROXPH G¶DLU QpFHVVDLUH
HW XQ QLYHDX VRQRUH EDV HW G¶pFRQRPLVHU GH O¶pQHUJLH /HV DWWpQXDWHXUV DFRXVWLTXHV DSSURSULpV UpGXLURQW OH
QLYHDX VRQRUH GHV YHQWLODWHXUV GDQV OHV ORFDX[
7RXWHV OHV JDLQHV GRLYHQW rWUH PXQLHV G¶XQH LVRODWLRQ GH  j  PP G¶pSDLVVHXU SRXU pYLWHU WRXWH FRQGHQVDWLRQ
Remarque : /H FDSWHXU GH WHPSpUDWXUH % GRLW rWUH PRQWp GDQV OD JDLQH G¶DLU VRXIÀp VRXV OH UpFKDXIIHXU
pOHFWULTXH YRLU OH VFKpPD IRQFWLRQQHO GDQV OH PDQXHO G¶LQVWDOODWLRQ pOHFWULTXH HW G¶XWLOLVDWLRQ GX V\VWqPH GH
commande). Il est nécessaire de laisser dans la gaine d'air droite de l'espace pour le montage du capteur, mais
aussi de laisser l'espace nécessaire pour les travaux de maintenance et d'entretien. L'espace minimal entre
O¶XQLWp HW OH FDSWHXU % GRLW rWUH OH GRXEOH GX GLDPqWUH GH OD JDLQH G¶DLU
/HV JDLQHV OHV pOpPHQWV HQ DFLHU HW OHV DXWUHV VHUYLFHV QH GRLYHQW SDV
reposer sur l'unité.
'DQV OH V\VWqPH GH JDLQHV SRXU OHV XQLWpV GRWpHV G¶XQ UpFKDXIIHXU G¶DLU
pOHFWULTXH XWLOLVHU XQ UHJLVWUH GH IHUPHWXUH G¶DLU VDQV PpFDQLVPH GH UDS-
SHO j UHVVRUW
,QVSHFWLRQ ¿QDOH
$SUqV LQVWDOODWLRQ GH O¶XQLWp XQH LQVSHFWLRQ DSSURIRQGLH GRLW rWUH UpDOLVpH &HOD GRLW LQFOXUH O¶LQVSHFWLRQ GH
O¶LQWpULHXU GH O¶XQLWp HW O¶pOLPLQDWLRQ GHV GpEULV HW RXWLOV TXH OHV SUHVWDWDLUHV SRXUUDLHQW DYRLU ODLVVp VXU SODFH
5HSODFHU OHV SDQQHDX[ TXL RQW pYHQWXHOOHPHQW pWp UHWLUpV HW IHUPHU WRXWHV OHV SRUWHV G¶DFFqV HQ YpUL¿DQW TXH
OHV MRLQWV G¶pWDQFKpLWp GHV SRUWHV Q¶RQW SDV pWp HQGRPPDJpV
4. MAINTENANCE
,O HVW UHFRPPDQGp GH UpDOLVHU OD PDLQWHQDQFH SpULRGLTXH GH O¶XQLWp GH WUDLWHPHQW G¶DLU  j  IRLV SDU DQ
/¶XQLWp HVW UHPSOLH GH JD] UpIULJpUDQW /¶HQWUHWLHQ GRLW rWUH UpDOLVp FRQIRU-
PpPHQW j OD OpJLVODWLRQ ORFDOH
Outre l'inspection de maintenance préventive, les opérations suivantes doivent être réalisées :
 9pUL¿FDWLRQ GH O¶pFKDQJHXU GH FKDOHXU URWDWLI /¶LQVSHFWLRQ GH O¶pFKDQJHXU GH FKDOHXU URWDWLI HVW UpDOLVpH
XQH IRLV SDU DQ /D YpUL¿FDWLRQ SRUWH VXU OD OLEUH URWDWLRQ GH O¶pFKDQJHXU GH FKDOHXU URWDWLI OD FRQWLQXLWp GH OD
FRXUURLH URWDWLYH O¶DEVHQFH GH GRPPDJHV VXU OHV URWRUV j WDPERXU HW OH MRLQW G¶pWDQFKpLWp ,O HVW QpFHVVDLUH
GH YpUL¿HU O¶pWDW GH OD FRXUURLH 8QH FRXUURLH GpWHQGXH JOLVVH HW QXLW j O¶HI¿FDFLWp GH O¶pFKDQJHXU GH FKDOHXU
URWDWLI 3RXU REWHQLU XQH HI¿FDFLWp PD[LPDOH OH URWRU GRLW WRXUQHU DX PRLQV  IRLV SDU PLQXWH 8Q pFKDQJHXU
GH FKDOHXU VRXLOOp HQWUDvQH XQH EDLVVH GH O¶HI¿FDFLWp 1HWWR\HU O¶pFKDQJHXU GH FKDOHXU DYHF XQ MHW G¶DLU RX OH
ODYHU j O¶HDX WLqGH 9HLOOHU j O¶DEVHQFH GH FKXWH G¶HDX VXU OH PRWHXU pOHFWULTXH
Distribué par ATIB : contact@atib.fr / KOMFOVENT fabriqué par : UAB AMALVA www.komfovent.com
Tuyau d'eau de condensation et drain à siphon
D*
2
SRXU IDFLOLWHU OH QHWWR\DJH HW JDUDQWLU OD GXUDELOLWp ,O HVW QpFHVVDLUH G¶XWLOLVHU OH
Schéma d'évacuation de l'unité horizontale
view 2
view 2
05/12/2016
Figure 3.1 d
 PP
10