Télécharger Imprimer la page

Publicité

Liens rapides

Installer: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
WARNING
!
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, ex-
plosion, or production of carbon monoxide may result,
causing property damage, personal injury, or loss of
life. The qualified service agency performing the work
assumes the responsibility for the proper conversion
of this appliance with this kit.
Regulator
Cover Screw
Plastic Regulator
Adjustment
Screw
Regulator
Regulator
Sleeve
Spring
Figure 1. 36C and 36D
Models
WARNING
!
VALVE CONVERTED FOR USE ON L.P.
GAS. IMPROPER OPERATION COULD
RESULT IN DEATH OR SERIOUS
INJURY.
MISE EN GARDE
!
SOUPAPE CONVERTIE POUR USAGE
SUR GAZ DE PÉTROLE LIQUÉFIÉ.
UN FONCTIONNEMENT INAPPROPRIÉ
PEUT PROVOQUER LA MORT OU DES
BLESSURES GRAVES.
WARNING Label
Figure 3. Contents of kit
Regulator
Plastic
Cover
Regulator
Screw
Adjustment
Screw
Regulator
Spring
Regulator
Sleeve
Figure 2. 36E, 36F,
36G, 36H and 36J
Single Stage
Models
L.P. Regulator
Spring
LP
L.P. Label
www.white-rodgers.com
www.emersonclimate.com
F92-0659 and F92-0836
Regulated Natural to L.P. Gas
Conversion Kit
INSTALLATION INSTRUCTIONS
APPLICATION
This regulated Natural Gas to regulated L.P. Gas conversion kit
allows the 36C, 36D, 36E, 36F, 36G, 36H and 36J Series gas
valves to be used on L.P. gas applications. This conversion kit
is for use on all single stage, fast and slow open models.
TO CONVERT FROM NATURAL TO L.P. GAS
1.
Remove regulator cover screw.
2.
Remove regulator adjustment screw (beneath the cover screw).
3.
Remove Natural Gas regulator spring from regulator sleeve.
4.
Insert the L.P . regulator spring (provided in the conversion kit)
into the regulator sleeve.
5.
Replace the regulator adjustment screw. Then adjust the out-
let pressure to the appliance manufacturer's specified outlet
pressure.
6.
Replace the regulator cover screw.
7.
Attach the WARNING label (provided in the kit) to the gas valve
where it can be readily seen. Also attach the small round L.P .
label to the top of the regulator cover screw.
8.
If present pilot burner is to be used, the pilot orifice must be
replaced.
Conversion back to Natural Gas use may be made at a later
date by retaining the Natural Gas spring (removed in step 3,
above) and following the same procedures (except for burner
pressure given in step 5).
NOTE
Two single stage kits may be used for 2-stage valve.
If the converted L.P. low regulator setting is less than
5.0" W.C., use the original natural gas spring.
PART NO. 37-5379G
Replaces 37-5379F
1342

Publicité

loading

Sommaire des Matières pour White-Rodgers F92-0659

  • Page 1 F92-0659 and F92-0836 Regulated Natural to L.P. Gas Conversion Kit INSTALLATION INSTRUCTIONS Installer: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.