A. UTILITIES / ALIMENTATION
CONDUITES D'ALIMENTATION
1 1/2 WASTE LOCATION
EMPLACEMENT DE
L'ÉVACUATION 1 1/2 po
22 1/2 [572 mm]
B. MOUNTING / MONTAGE
* 30 7/8 [784 mm]
* Yields a finished rim height of 33" [832 mm]
Donne une hauteur de rebord d'évier fini de 33
po [832 mm]
Recommended carrier Franke IWC2203
Support mural Franke recommandé IWC2203
31420
0321
WALL OPENINGS LAYOUT
DISPOSITION DES OUVERTURES
DANS LE MUR
SUPPLY LINES
20 1/4 [515 mm]
5 [127 mm]
6 5/16 [160 mm]
2 1/2 [64 mm]
4 [102 mm]
H
C
7 1/2 [191 mm]
3 1/16 [78 mm]
FINISHED FLOOR / PLANCHER FINI
5 [127 mm]
2 1/2 [64 mm]
5 [127 mm]
17 5/16 [440 mm]
5 [127 mm]
FINISHED FLOOR / PLANCHER FINI
SINK & SHROUD OUTLINE
CONTOUR DE L'ÉVIER & LA JUPE
GFI OUTLET LOCATION
EMPLACEMENT DE LA PRISE
PROTÉGÉE PAR UN GFI
23 1/2 [597 mm]