Draining Pump
1. Pump down water level below all inlets to the pool.
To avoid dangerous or fatal electrical shock hazard,
turn OFF power to motor before draining pump.
2. Cap inlet piping after draining to keep water out of the
pipes.
3. To prevent pump from freezing, drain the pump body
through the drain fitting provided.
4. Be sure motor is kept dry and covered.
Startup For Winterized Equipment
Hazardous voltage.
Can shock, burn,
or cause death.
Disconnect power
before working
on pump or motor.
6. Remove any winterizing plugs in piping system.
7. Drain all antifreeze from system.
8. Close all drain valves and replace all drain plugs in
piping system.
9. Prime pump according to instructions on Page 6.
1. Remove any temporary
weather protection placed
around system for
shutdown.
2. Follow filter manufacturer's
instructions for reactivation
of the filter.
3. Inspect all electrical wiring
for damage or
deterioration over the
shutdown period. Have a
qualified serviceman repair
wiring as needed.
4. Inspect and tighten all
watertight connections.
5. Open all valves in suction
and return piping.
PUMP SERVICE
Hazardous voltage.
Can shock, burn,
or cause death.
Disconnect power
before working
on pump or motor.
If shaft seal is worn or damaged, repair as follows:
Pump Dissasembly/Removing Old Seal
Disconnect power to pump motor.
Be sure gate valves on suction and return piping
are closed before starting work.
Release all pressure by opening all vents before
starting work.
1. Drain pump through drain fitting on bottom of pump
body.
2. Remove 6 nuts, lockwashers and flat washers
holding seal plate to pump body. Pull seal plate and
motor away from pump body. (You may have to
CAREFULLY use a screwdriver to separate body
from seal plate.)
3. Remove seven screws and washers holding diffuser
to seal plate. Remove diffuser.
4. Remove motor canopy. Being careful not to touch
capacitor terminals, loosen capacitor clamp and
move capacitor to one side.
5. Hold shaft with 7/16" open-end wrench on motor
shaft flats.
6. Unscrew impeller from shaft (turn counterclockwise
when facing it).
7. Remove four screws holding seal plate to motor.
7
Pump should only be serviced
by qualified personnel.
Be sure to prime pump (Pg.
6) before starting.
1. STOP PUMP before
proceeding.
2. CLOSE GATE VALVES in
suction and discharge pipes.
3. RELEASE ALL PRESSURE
from pump and piping system.
To avoid dangerous or
fatal electrical shock
hazard, turn OFF power to
motor before working on
pump or motor.