Before you start:
Window Requirements:
Your new room air conditioner is factory prepared for easy installation
in a horizontal sliding or casement type window with a minimum width
of 15 1/2 inches. Unit will fit a 42 inch high window opening as
received from factory.
D
A
B
C
E
Sliding Window Installation
1.
Choose the installation site. It is imperative that window frame
assembly and side of structure are adequate to support weight of
unit. Reinforce if necessary.
2.
Slide open one window sash to install support platform.
3.
Attach support platform to sill plate with three (3) 3/8" long self-
tapping screws (Fig. 3).
4.
Loosely attach support angle to bottom of support platform using
two (2) 7/16" long machine screws, flat washers, and nuts.
5.
Place support platform against lower window track and firmly
against vertical edge of window frame (Fig. 4).
6.
Attach support platform to window sill using two (2) 1" long
self-tapping screws (Fig. 4).
If required, overcome interference of support platform with
window track or storm windows by securely attaching a shim
strip to the window sill. Strip should be as long as width of
support platform and flush with back edge of sill. Thickness of
strip should be controlled by amount of interference.
7.
Pull support angle against outside of structure. Tighten two (2)
7/16" long machine screws on top of support platform (Fig. 3).
8.
Adjust leveling bolt to position support angle in a level plane.
This will allow for proper angle. Tighten leveling bolt locknut
(Fig. 3).
Important: Unit must be level or tilted back slightly to facilitate proper
condensate disposal.
Make sure unit is unplugged before removing the
decorative front.
It is recommended that you have help to install your unit
and that you use proper lifting technique to avoid
personal injury.
Make sure unit is unplugged before removing chassis
from cabinet.
Use caution when working around exposed sharp edges
of the cabinet and sharp coils to avoid injury or torn
clothing.
Installation Parts Kit
Fastener Identification
Description
1" long wood screws
A
3/8" Self tapping screws
B
7/16" mach. screws/nuts
C
Leveling Bolt/ Nut
D
Speed Clips
E
Tools Needed
Quantity
2
7
2
1
2
The installation is intended to be permanent, and when installed in
apartment or rental properties, permission to make modifications
should be obtained from owners or landlords of buildings prior to
installation of unit.
Fig. 3
Support Platform
A
7/16" mach. screws
B
3/8" Self tapping screws
C
Sill plate
D
Fig. 4
1" long screws
A
Support Platform
B
Lower window track
C
3
INSTALLATION
WINDOW INSTALLATON
Screwdrivers
Knife
Tape Measure
Drill
Carpenter's Level
SUPPORT PLATFORM ASSEMBLY
B
A
E
F
Support Angle
E
Leveling Bolt
F
A
A
B
C
E
Window Sill
D
Shim Strip
E
C
D
D

Publicité