Publicité

machine components and cause electric
shocks.
– Switch of the power tool immediately
if the tool is blocked. Always be pre-
pared for high reaction torques that
can cause kickback.
The tool blocks if:
- the power tool is overloaded or - it be-
comes jammed in the workpiece being pro-
cessed.
– Avoid unintentional activation. Ensure
that the on/off switch is in switched-
off position before inserting a battery.
Carrying the power tool with your finger at
the on/off switch, or inserting the battery
when the power tool is switched on, can re-
sult in accidents.
– The machine must never be operated
when wet or located in a damp envi-
ronment. Connect devices that you intend
to use outdoors via an earth leakage circuit
breaker (FI) with a maximum release cur-
rent of 30mA. Always use a cable approved
for outdoor use.
– Wear suitable protection: such as ear
protection, safety goggles, a dust mask for
work which generates dust, and protective
gloves when working with raw materials
and when changing tools.
– Secure the workpiece using clamping de-
vices.
– Check the plug and the cable regularly and
should either become damaged, have
them replaced by an authorised after-sales
service workshop.
– Always guide the cable backwards away
from the machine.
– Take care when drilling into walls as there
is a danger of rupturing concealed gas/wa-
ter pipes or cutting through power cables.
DRP 18-4 DEC FF/ PDP 20-4 DEC FF
6
Operation
WARNING
Unauthorised voltage or frequency!
Risk of accident
The mains voltage and the frequency of
the power source must correspond with
the specifications on the machine's name
plate.
WARNING
Risk of injury, electric shock
Always pull the plug out of the socket be-
fore performing any type of work on the
machine!
6.1
Switch on/off
On/off switch [1-7]
Press = ON, release = OFF
The speed of the machine depends on
how far the on/off switch is pressed in.
Speed set button[1-4]
Press once = ON, press twice or press on/off
switch = OFF
6.2
Attaching the additional handle
[2]
Always use the additional handle.
Position the additional handle [2-2] on
the extension of the gearbox housing and
engage the recesses on the additional handle
in the lugs on the housing.
Turn the handle until secured in position.
Turn the handle to adjust the position in
30° increments.
The drilling depth can be adjusted using
the depth stop [2-1].
7
Settings
7.1
Changing the rotational direc-
tion [1-8]
• Switch to the left = clockwise
• Switch to the right = anticlockwise
7.2
Changing gear [1-6]
Only press the speed switch when the
machine is off. Otherwise there is a
danger of damaging the gearbox.