IMPORTANT INSTRUCTIONS -
Model: AKCV30
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
1.
Read all instructions before installing or using the central vacuum.
2.
Use this central vacuum only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electrical shock,
or injury to persons.
WARNING:
DO NOT DEPEND UPON THE UNIT'S CONTROLS AS THE
SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING.
ALWAYS UNPLUG THE UNIT.
3.
Before servicing or cleaning the unit, unplug the unit.
4.
Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-
related construction.
5.
Make certain that the power source conforms to the electrical requirements
of the unit.
CAUTION:
THIS UNIT MUST NOT BE USED IN POTENTIALLY
DANGEROUS LOCATIONS SUCH AS FLAMMABLE, EXPLOSIVE, CHEMICAL-
LADEN OR WET ATMOSPHERES.
6.
When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
CAUTION:
EXHAUST SHOULD NOT BE VENTED INTO A WALL, CEILING,
OR CONCEALED SPACE WITHIN THE HOME.
7.
This unit is not intended for use on wet or outdoor locations, flammable or
combustible liquids, burning or smoking items such as cigarettes, matches,
or hot ashes.
AKCV30 New 11-06
OPERATING MANUAL
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
8.
The central vacuum must be grounded as a precaution against possible
electrical shock.
9.
Do not use with damaged cord or plug.
10. Do not insert any objects into openings other than acceptable hose
connections.
11. Use extra care when vacuuming on stairs.
12. To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
ELECTRICAL REQUIREMENTS
WARNING:
CONDUCTOR CAN RESULT IS A RISK OF ELECTRIC SHOCK. CHECK WITH A
QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO
WHETHER THE OUTLET IS PROPERLY GROUNDED. DO NOT MODIFY THE PLUG
PROVIDED WITH THE UNIT- IF IT WILL NOT FIT THE OUTLET, HAVE A PROPER
OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN.
WARNING:
AND HAS A GROUNDING PLUG. MAKE SURE THAT THE UNIT IS CONNECTED
TO AN OUTLET HAVING THE SAME CONFIGURATIONS AS THE PLUG. NO
ADAPTER SHOULD BE USED WITH THIS UNIT.
This unit requires a dedicated, grounded electrical outlet of 120 volts AC, 60 Hz,
15 amp circuit.
www.airkinglimited.com
Central Vacuum
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
IMPROPER CONNECTION OF THE EQUIPMENT-GROUNDING
THIS UNIT IS FOR USE ON A NOMINAL 120 VOLT CIRCUIT
1 of 12

Publicité

loading

Sommaire des Matières pour AirKing AKCV30

  • Page 1 This unit is not intended for use on wet or outdoor locations, flammable or 15 amp circuit. combustible liquids, burning or smoking items such as cigarettes, matches, or hot ashes. SAVE THESE INSTRUCTIONS AKCV30 New 11-06 1 of 12 www.airkinglimited.com...
  • Page 2 18" above the finished floor. 2. To protect the system during the drywall phase of construction, an optional CVIV80 plaster guard can be utilized and should be installed at this point. AKCV30 New 11-06 2 of 12 www.airkinglimited.com...
  • Page 3 Check that the tubing is evenly seated in NOTE: The electrified wall inlet should be listed on the inspection report for the fitting and is aligned properly with the rest of the line (Figure 10). building inspection purposes. AKCV30 New 11-06 3 of 12 www.airkinglimited.com...
  • Page 4 (Figure 11). 7. Angle the mounting plate and elbow into the previously cut hole in the wall and make the connection with the tubing (Figure 20). AKCV30 New 11-06 4 of 12 www.airkinglimited.com...
  • Page 5 Please call: 1-800-465-7300, MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4:00 PM EST. PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. Reference the type and style of product (located on label on product) when you call. For more information please visit our website: wwwairkinglimited.com AKCV30 New 11-06 5 of 12 www.airkinglimited.com...
  • Page 6 AKCV30 New 11-06 6 of 12 www.airkinglimited.com...
  • Page 7 Cette unité requiert une prise de courant dédiée, de 120 volts AC, 60 Hz, mise ou des cendres chaudes. à la terre, à circuit de 15 ampères. SAVE THESE INSTRUCTIONS AKCV30 New 11-06 7 of 12 www.airkinglimited.com...
  • Page 8 (Figure 2). La conduite REMARQUE: La hauteur d’installation dépendra de la préférence personnelle, mais la prise est généralement installée à 46 cm (18 po) du sol. AKCV30 New 11-06 8 of 12 www.airkinglimited.com...
  • Page 9 être installées. Commencer par vérifier qu’aucun débris n’a été 1" laissé sur les plaques de montage après le travail de construction et de Figure 9 Figure 10 finition et les nettoyer au besoin. AKCV30 New 11-06 9 of 12 www.airkinglimited.com...
  • Page 10 (Figure 19) (voir l’étape 7 dans la section de l’installation du tube pour les instructions de collage). Support de Entrée montage Trous Plaque de montage de vis Figure 21 Figure 22 Figure 19 Figure 20 AKCV30 New 11-06 10 of 12 www.airkinglimited.com...
  • Page 11 VEUILLEZ NE PAS RETOURNER CE PRODUIT À L’ENDROIT DE L’ACHAT D’ORIGINE. Référencer le type et le style du produit (situé sur l’étiquette du produit) lorsque vous appelez. Pour plus d’information, veuillez visiter le site Web de Air King au www.airkinglimited.com AKCV30 New 11-06 11 of 12 www.airkinglimited.com...
  • Page 12 AKCV30 New 11-06 12 of 12 www.airkinglimited.com...