The Aqua Pro is a heavy-duty water pump that provides high volume water flow with reduced pump cycling, thanks to the
large five-chamber diaphragm. Quick Attach Fittings make installation or replacement easy. The Aqua Pro is designed to
run on water systems with no accumulator tank necessary, and up to five fixtures! It is also suited for use with a holding
tank water system, as may be found in a boat, RV or remote cabin. It provides up to 5.5 gallons per minute. The Aqua
Pro is self-priming, and can run dry without damage. This automatic demand water system pump has a built-in pressure
switch, which automatically starts and stops and stops the pump when the faucet is opened and closed.
FEATURES
• 5 chamber diaphragm pump
• Run dry capable for normal
workloads
• Self priming
APPLICATIONS
• Yacht/RV/caravan pressurized
water system
• Sprayer fixtures (vehicle-mounted
sprayers, electric sprayers)
INSTALLATION
MATERIALS:
Aqua pump with related accessories
• 2 (at least) pieces of flexible, reinforced hose piping, with collapsing strength of twice the inlet collapsing
pressure( hose must be minimum 3/4" ID)
• 4 stainless steel hose clamps and screws
• 4 screws to fasten the pump to the mounting surface
• 1 electrical cutoff switch
• 1 fuse
• 1 screwdriver
• 1 strong cutting implement for tubing
• (if desired) Teflon tape or sealant
SETUP
1. The pump may be mounted in any position. If mounted vertically, the pump head should be in the down
position to avoid leakage into the motor casing in the event of a malfunction.
2. Secure the feet, but do not compress them. Overtightening the securing screws may reduce their ability
to dissipate noise and vibration.
3. Intake hose must be minimum 3/4" (19 mm) ID reinforced hose. Main distribution line from pump outlet
should also be 3/4" (19 mm) ID with branch and individual supply lines to outlets no smaller than 3/8"(10
mm).
4. Plumb the system using high pressure (2x pump rating), braided, flexible tubing to minimize vibration/
noise.
5. Do not apply inlet pressure in excess of 30 psi. In general, try to avoid any inlet pressure completely.
AQUA PRO PUMP MANUAL
320-5100, 320-5200
• Continuous duty
• Automatic: controlled by pressure
switch
• Quiet Operation
• Cleaning machines, humidifier,
water purification, medical
apparatus
• Food beverage filling & liquid
transfer
page
1
• Industry standard mounting
pattern
• Ignition protected
• Solar water system
• Any other pressurization system

Publicité

loading

Sommaire des Matières pour Airxcel InVision 320-5100

  • Page 1 AQUA PRO PUMP MANUAL 320-5100, 320-5200 The Aqua Pro is a heavy-duty water pump that provides high volume water flow with reduced pump cycling, thanks to the large five-chamber diaphragm. Quick Attach Fittings make installation or replacement easy. The Aqua Pro is designed to run on water systems with no accumulator tank necessary, and up to five fixtures! It is also suited for use with a holding tank water system, as may be found in a boat, RV or remote cabin.
  • Page 2 6. Avoid any kinks or fittings which could cause excessive restrictions. 7. Strainer should be attached to the inlet side. 8. The fittings must be secured to avoid leakage. 9. Use clamps at both ends of hose to prevent air leaks into the water line. 10.
  • Page 3 DESCRIPTION QUANTITY PUMP HEAD ASSEMBLY VALVE ASSEMBLY DIAPHRAGM ASSEMBLY MOTOR ASSEMBLY PRESSURE SWITCH DIAPHRAGM OF PRESSURE SWITCH QUICK ATTACH CLIP PUMP HEAD DIAPHRAGM RUBBER FEET MOTOR TROUBLESHOOTING PULSATING FLOW- PUMP CYCLES ON AND OFF • Check lines for kinks. • Plumbing lines or fittings may be too small. •...
  • Page 4 LOW FLOW AND PRESSURE • Air leak at pump intake. • Accumulation of debris inside pump or plumbing. • Worn pump bearing (possibly accompanied by loud noise). • Punctured diaphragm. • Defective motor. NOISY • Check if the mounting feet are compressed too tightly. •...
  • Page 5 MANUEL DE LA POMPE AQUA 320-5100, 320-5200 L’Aqua Pro est une pompe à eau robuste qui fournit un débit d’eau à haut volume avec un cycle de pompe réduit, grâce au grand diaphragme à cinq chambres. Les raccords de fixation rapide facilitent l’installation ou le remplacement.
  • Page 6 4. Raccorder la tuyauterie pour le système en utilisant des tubes flexibles tressés à haute pression (2 fois la capacité de la pompe) afin de minimiser les vibrations et le bruit. 5. Ne pas appliquer une pression d’entrée supérieure à 30 psi. En général, essayer d’éviter complètement toute pression d’entrée.
  • Page 7 TROUSSES DE RÉPARATION CLÉ DESCRIPTION QUANTITÉ ENSEMBLE TÊTE DE POMPE ENSEMBLE VANNE ENSEMBLE MEMBRANE ENSEMBLE MOTEUR PRESSOSTAT MEMBRANE DE PRESSOSTAT ATTACHE À FIXATION RAPIDE TÊTE DE POMPE MEMBRANE PIEDS EN CAOUTCHOUC MOTEUR DÉPANNAGE DÉBIT PULSATOIRE – CYCLE DE LA POMPE ACTIVÉ ET DÉSACTIVÉ •...
  • Page 8 LE MOTEUR NE S’ALLUME PAS • Câblage desserré ou incorrect. • Le circuit de la pompe n’est pas alimenté. • Fusible grillé ou protection thermique déclenchée. • Problème de pressostat. • Moteur défectueux. LA POMPE NE S’ARRÊTE PAS APRÈS AVOIR ÉTEINT TOUS LES APPAREILS •...

Ce manuel est également adapté pour:

Invision 320-5200