Télécharger Imprimer la page

Europlast eextra EET100T Mode D'emploi page 44

Publicité

Caution! Read the manual carefully before installing and using of the fan.
Caution! Make sure that there are no visual defects when unpacking the fan.
Caution! We do recommend you to save the bill of purchase with stamped guarantee coupon, for the
purpose of possible reclamation. Otherwise guarantee will be not in legal force.
Caution! Before connecting to the mains supply ensure that mains voltage (V) and frequency (Hz)
corresponds to the parameters on the rating plate.
Caution! When connecting the fan, it is important to follow the polarity (see Installation and
Maintenance)
Caution! This device may be used by children starting from age of 8 as well as people with physical or
mental disorders, given that they are familiar with the manual and safety provisions in respect to this
device. It is prohibited for children to play with the device. Children may not carry out maintenance
or cleaning of this device without supervision of adults.
Technical information
Voltage (V)
Phase (Hz)
Power (W)
Suction power (m
/h)
3
Noise level: 3m distance, L
Protection against environmental factor
RPM
Ambient temperature
Weight (kg)
Sizes,
EET100
mm
A
145
B
145
C
80
D
99
E
35
Installation and Maintenance
Caution! Before installation, disconnect the power network where you are planning on installing the
fan.
Caution! Installation may be carried out only by a qualified electrician.
Before mounting, the cover part of the ventilator must be removed by pressing with a screwdriver on two locks
under the case (Image 1). The ventilator must be mounted in a ventilation duct by attaching the ventilator on the
wall by the use of screws (Image 2). The base model ventilators, ventilators with a switch (W), ventilators with a
timer (T), ventilators with a humidity sensor and timer (HT) must be connected to the electrical network. Under
the cover, there are N-L or N-L-S clamps to which the electrical network must be properly connected (Images 3-5).
When connecting the ventilator with the voltage, it is important to observe polarity and connect the line wire
with L-clamp and neutral wire with N-clamp. When connecting the fan to electricity, it is important to take into
account polarity and connect the live wire to the Terminal L and the neutral wire to the Terminal N.
In case if the fan is directly connected to the electric power network, the power network must be equipped with a
switch that ensures safe disconnection of the power supply.
A dB(A)
p
EET120
EET125
170
170
170
170
80
80
119
124
35
35
EET100
15
100
32
2550
0,43
EET150
195
B
195
80
149
35
44
EET120
EET125
220 - 240
50
16
16
145
150
34
36
IPX4
2400
2360
+5°C ... +40°C
0,52
0,52
D
A
EET150
20
200
40
2100
0,66
C
E