This kit includes:
1 blower and housing assembly
2 #8 x ½" screws
1. Turn off any electrical
power to fireplace.
2. Ensure that the access
cover plate has been in-
stalled.
3. Remove the on/off switch bracket and the cover plate
below it. The switch spacers and cover plate may now be
discarded.
4. Decide which side of the blower housing you prefer the
on/off switch to be located on.
NorthlineExpress.com
GS-64KT BLOWER KIT
INSTALLATION INSTRUCTIONS
GA-010-634
5. Remove the 2 screws from the top outer edge of the rear
WS-570-18
stove panel. The housing is mounted using these two holes,
as well as two other holes located in the rear panel.
COVER PLATE
LOCATION
ACCESS PLATE LOCATION
6. Mount and secure the blower housing using 4 screws.
Ensure that the on/off switch wires pass through the appro-
priate slot located on either side of the blower housing.
7. Remove the 2 screws from the side of the blower housing
that you want the switch to be located on and resecure the
on/off switch.
8. Turn on any electrical power to the fireplace
Because the blower is thermally activated, when turned on,
it will automatically start approximately 15-30 minutes after
lighting the stove and will run for approximately 30-45 min-
utes after the stove has been turned off. Use of the fan
increases the output of heat.
http://www.northlineexpress.com
WS-415-161 / 09.01.99
SLOT
REMOVED SCREWS
Toll-Free 1-866-667-8454