Télécharger Imprimer la page

TotalPond 800 GPH Mode D'emploi page 4

Publicité

OPERATION INSTRUCTIONS (CONT.)
Step 2. Adjust the flow control to
the lowest setting. Once the pump
has been turned on (after step 3)
you may adjust the flow control to
the preferred setting.
Step 3. Place the pump into the
water and connect to a properly
grounded electrical outlet.
SPECIFICATIONS
800 GPH (at 0 ft.)
Max Flow Rate
13.9 ft. (at 0 GPH)
Max Pumping Height
52 watts / 1 amps
Power Consumption
16 ft.
Cord Length
Register your product online!
Use your smartphone camera
to scan the QR code or visit our
website totalpond.com/register
6
Visit WWW.TOTALPOND.COM for information and tips.
2
3
Flow Rates (GPH)
12
130
190
11
10
243
9
285
8
322
7
362
6
412
5
470
4
528
589
3
2
650
1
713
0
800
Before installing your pump please write down the following information:
The 14 digit serial number located on the pump
___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Item number:
Date of purchase:
___ /___ /___
______
item number
MAINTENANCE & TROUBLESHOOTING
Always disconnect units from the power source before
beginning any maintenance or work on the unit.
Regular cleaning of the pump may be necessary depending
upon the environment in which it is operated. Clean the pump
when it is visibly soiled or when a drop in performance is
detected.
Step 1. Remove the inlet
screen.
Step 2. Remove the
impeller housing to expose
the impeller assembly.
Step 3. Remove the
impeller assembly by gently
pulling on the impeller
blades. The impeller is held
in place by a manget
Step 4. Use a soft cloth
or brush and warm water
to clean the impeller, the
inside of the impeller
housing and the rotor
housing.
Step 5. Reassemble all
pump parts and place in
water before reconnecting
to the power source.
Please call Customer Care before returning item to store: 1-888-412-6001
Pump date code:
____ /____
mm
yy
00000000000000
1
2
3
4
5
7

Publicité

loading

Ce manuel est également adapté pour:

3028 lph52676