Télécharger Imprimer la page

Lotus H470W Instructions De Montage Et Mode D'emploi page 17

Masquer les pouces Voir aussi pour H470W:

Publicité

Lotus heating Systems A/S
Model identifier: H570T
Indirect heating function: NA
Direct heat output: 6 kW
Fuel
Preferred fuel
Wood logs,
moisture
content ≤ 25 %
Compressed
wood,
moisture
content < 12 %
(e.g. according
to ISO
17225-3
Other woody
biomass
Non-woody
biomass
Anthracite and
dry steam coal
Hard coke
Low
temperature
coke
Bituminous
coal
Lignite
briquettes
Peat briquettes
Blended fossil
fuel briquettes
Other fossil
fuel
Blended
biomass and
fossil fuel
briquettes
Other blend of
biomass and
solid fuel
Heat output
Nominal heat output
Minimum heat output
Auxiliary power consumption
At nominal heat output
At minimum heat output
In standby mode
www.lotusstoves.com
Other
suitable
fuel(s)
yes
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
Symbol
P nom
P min
el max
el min
el SB
+45 63 23 70 70
Local heating emissions
at nominal heat output
[x] mg/Nm³ (13%O2)
ηs
PM
OGC
[x%]:
70,5
19,4
89
Value
7
N.A.
N.A.
N.A.
N.A.
Emissions from local
heating at minimal
rated heat output
[x] mg/Nm³ (13%O2)
CO
NOX
PM
OGC
1250
135
NA
NA
Unit
kW
kW
kW
kW
kW
CO
NOX
NA
NA

Publicité