Electronic timers
DAA01, PAA01
DAA51, DAA71
DBA52
DMB01, PMB01
DMB51, DMB71
Connections
L(+)
µ
µ
A1
16
18
26
28
A2
15
25
DAA01C...
DAA01D...
DAA01D
DAA71D
N(-)
DAA
DAA51
L(+)
µ
µ
26
28
A1
16
18
S
Y1
A2
25
15
DMB01C...
DMB01D...
DMB01D...
DMB71D
N(-)
DMB51C...
DBA, DMB
DBA52...
Settings
ON:
instantaneous
OFF:
delayed
according to
the first relay
Adjustment
Check if the connections are correct. Turn the
power supply ON, the green LED switches ON.
The working mode, according to the selected
function, is schematized on the side label.
The yellow LED is ON when the relay is ener-
gized, it blinks slowly during timing and blinks
fast in case of wrong set-up.
Installation instructions
Code 8022344/190724 INSTRUCTION SHEET
XAAX1_XMBX1_XBAX2_RENEWAL_V4
www.gavazziautomation.com
L(+)
µ
µ
2
4
3
8
9
10
1
11
1
PAA01C...
PAA01D...
PAA01D
N(-)
PAA
L(+)
µ
µ
2
4
3
8
9
S
5
10
1
11
PMB01C...
PMB01D...
PMB01D...
N(-)
PMB
Select the desired time range by the lower dial on
front as shown on the left.
Adjust the time period on relative scale: 1 to 10
with respect to the chosen range, setting the
centre knob as shown on the left.
XAA01D and XMB01DM24B002: select the
desired function of the second relay output by the
DIP-switch on the front (OFF=delayed according
to the first relay, ON= instantaneous).
Mounting
Hang the device to the DIN-Rail being sure that
the spring closes. Use a screwdriver to remove
the product.
Scan to read me in your language!
Scannen Sie, um mich in Ihrer Sprache
zu lesen!
Scanne pour me lire dans ta langue !
Connect the power supply to the proper terminals. Connect the trigger input S between terminals
A1 and Y1 (DBA52 and DMBX1 versions only). Connect the relay output according to the ratings as
6
5
7
shown in the side diagrams.
4
8
3
9
Keep power OFF while connecting!
2
10
1
11
L(+)
N (-)
DAA, DBA, DMB PAA, PMB Terminals
A1, A2
A1, Y1
15, 16, 18
6
5
7
4
8
25, 26, 28
3
9
2
10
1
11
Y1, A2
L(+)
N (-)
Each terminal can accept up to 2.5 mm
DMB51 and DMB71 and 2 x 2.5 mm
DAA01
PAA01
DAA51
DAA71
DBA52
Packaging
The packing material should be kept for redeliv-
ery in case of replacement or repair.
¡Escanea para leerme en tu idioma!
Scansiona per leggermi nella tua lingua!
Scan for at læse mig på dit sprog!
扫码后选择相关语言进行阅读!
2, 10
Power supply
Trigger input
2, 5
(DBA52, DMB, PMB)
1, 3, 4
Relay output
2nd relay output
8, 9, 11
(DAA01D, DAA71, PAA01D, DMB01D,
PMB01D)
5, 10
Additional load (DBA52, DMB, PMB)
2
wires for DAA51, DAA71, DBA52,
wires for DAA01 and DMB01.
2
DMBX1 and PMB01: select the desired function
by the upper knob as shown on the left:
Op: Delay on Operate
In: Interval
DMB01
Io: Interval on trigger open
PMB01
DMB51
Id: Double Interval
DMB71
Dr: Delay on release
R: Symmetrical recycler (ON first)
Rb: Symmetrical recycler (OFF first)
CE-marking and approvals
Tightening torque
DAA01, DMB01
DAA51, DAA71,
DBA52, DMB51,
DMB71