The appliance didn't heat up,
or only ventilator worked
Abnormal noise
INSTRUCTIONS FOR DISPOSAL
Disposal of this product shall be governed by the European Community Directive 2012/19/UE on Waste Electrical and Electronic
Equipment (WEEE). According to this regulation, the consumer has the obligation NOT to dispose of this product as household waste
but through separate channels of collection (WEEE). In the case of purchasing a similar new product, this product can be
disposed free of charge from the distributor. The disposal is free, no purchase required, for WEEE small size (external
dimensions below 25 cm). Comply with local regulations in the fields of waste disposal. It is always possible to dispose of this
product at a WEEE collection center predisposed by the public administration. The incorrect disposal of this article could have
potential adverse effects on the environment and human health. This symbol indicates the consumer's duty to dispose of this
article as WEEE and NOT as household waste. Improper disposal of the product by the consumer involves the application of
administrative sanctions provided by law.
Model: 65330EL
Item
Heat output
Nominal heat output
Minimum heat output
(indicative)
Maximum continuous
heat output
Auxiliary electricity consumption
At nominal heat output
At minimum heat output
In standby mode
Contact details
Kemper srl – Via Prampolini 1/Q – 43044 Lemignano di Collecchio (PR) – Italy
DT Istr (65330EL)_03/19_REV.1_09/19
The air inlet grill is blocked
The switch was not put at heating
setting.
The thermostat operated
The self-resetting cut-out operated
The appliance is not standing
upright
Symbol
Value
Unit
P
3,3
kW
nom.
2,2
P
kW
min.
P
3,3
kW
max,c
el
NA
kW
max
el
NA
kW
min
el
0
kW
SB
Keep the heater far away from articles
like curtain, plastic bag, paper and
other things which can cover the air
inlet.
Turn the switch to heat setting
Turn the thermostat and listen if there
is open/close voice. If there is no click
and the thermostat is not damaged, the
heater will automatic switch on when
the appliance cooled down
Turn the heater off and inspect the
blockage of inlet or outlet. Disconnect
the plug and wait at least 10 minutes
for the protection system to reset
before attempting to restart the heater.
Put the heater on a level surface
Type of heat input, for electric storage local space
heaters only (select one)
manual heat charge control, with integrated
thermostat
manual heat charge control with room and/or
outdoor temperature feedback
electronic heat charge control with room and/or
outdoor temperature feedback
fan assisted heat output
Type of heat output/room temperature control (select
one)
single stage heat output and no room temperature
control
Two or more manual stages, no room temperature
control
with mechanic thermostat room temperature control
with electronic room temperature control
electronic room temperature control plus day timer
electronic room temperature control plus week
timer
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window
detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
14/20
Item
65330EL
Unit
NO
NO
NO
NO
NO
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO