Fault
The appliance is leaking
water
The appliance is leaking
water
The appliance is
unusually loud
The display lamp does
not light
8
FB046-FB047-FB048-FB049_ML_A5_v3_20240801.indb 8
FB046-FB047-FB048-FB049_ML_A5_v3_20240801.indb 8
Probable Cause
The appliance is not properly
levelled
The discharge outlet is blocked
Movement of water to the drain is
obstructed
The water container is damaged
The drip tray is overflowing
Safety band not removed
Loose nut/screw
The appliance has not been
installed in a level or stable position
Replace lamp
Solution
Adjust the screw feet to level the appliance (if
applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Consult a qualified Technician
Empty the drip tray (if applicable)
Remove the safety band
Check and tighten all nuts and screws
Check installation position and change if
necessary
Consult a qualified Technician