spark Arrester
The spark arrester must be cleaned regularly to keep it functioning as
designed.
A clogged spark arrester:
• Prevents the flow of exhaust gas
• Reduces engine output
• Increases fuel consumption
• Makes starting difficult
If engine has been running, the muffler and the spark arrester will be 
very hot. Allow the muffler to cool before cleaning the spark arrester.
How To remove The spark Arrester
1. Remove the flange bolts from the muffler cover and remove the muffler     
    cover.
2. Remove the special screw from the spark arrester and remove the  
    spark arrester from the muffler.
Clean The spark Arrester screen
1. Use a brush to remove carbon deposits from the spark arrester screen.
    Be careful to avoid damaging the screen.
2. The spark arrester must be free of breaks and holes. Replace the
    spark arrester if it is damaged.
3. Install the spark arrester, and muffler protector in the reverse order
    of disassembly.
If you have any problems with the operation of your generator, please 
call the generator help line at 1-855-850-6668. If calling for assistance, 