1. Terminal Explanation
LS25, LS35, LS50, LS75
(1) L : Input terminal
(2) N : Input terminal
(3) FG
: Functional Ground
(4) - V : - Output terminal
(5) +V : + Output terminal
(6) Output voltage adjustable trimmer
(7) Output monitoring indicator (Green LED : ON)
LS100, LS150
(1) L : Input terminal
(2) N : Input terminal
(3) FG
: Functional Ground
(4) -V : - Output terminal
( 25A max./ terminal)
(5) +V : + Output terminal
( 25A max./ terminal)
(6) Output voltage adjustable trimmer
(7) Output monitoring indicator (Green LED : ON)
2. Terminal connecting method
Input must be off when making connection.
Connect FG terminal to ground terminal of the equipment.
The output load line and input line shall be separated and twisted to improve noise immunity.
LS25, LS35, LS50, LS75
-
LOAD
+
Maximum output current of each output terminal is 25A except for LS25 (15A).
If more than 25A, use 2 terminals.
Live line (Fuse in line)
Neutral line
Live line(Fuse in line)
Neutral line
LS100, LS150
-
LOAD
+
1
TDK-Lambda
LS
Series
25-150
INSTRUCTION MANUAL
1
2
3
4
5
1
2
3
4
5
6
7