Temperature setting
By pressing either of the buttons
the "Change the set temperature" mode. The display
starts flashing and it shows the temperature which has
been set so far. By pressing the buttons you can change
the temperature setting either up or down. If you don't
press any button for 5 seconds, the new setting will be
stored and the appliance with automatically go into
"Heating" mode. If you keep pressed any of the buttons
or
for more than 0.7 seconds, the value of the set
temperature will start increasing or decreasing by 4 units
per second. The temperature setting ranges from 10 to 30
degrees Celsius.
"Delayed start" of the panel convector
When the convector is in Off mode, by pressing the
"Timer" button you can enter a specific time after which
the appliance will automatically go in "Heating" mode.
This mode is indicated by a blinking yellow LED and
inactive red LED. The digital display will show the room
temperature when the Temperature LED is lit, and it
will show the remaining time in hours until "Heating"
mode will be activated and this will be indicated with
a lit Timer LED. Upon activating this mode the yellow
LED becomes lit, and the display starts flashing and
showing the entered time in hours until the convector
will be automatically switched on. Initially the display
will show 12 hours, and by using the
you can adjust the desired time. If you keep pressed any
of the buttons
or
for more than 0.7 seconds, the
value of the set time will start increasing or decreasing
by 4 units per second. If you don't press any button for 5
seconds, or if you press the Timer button, the regulator
will automatically go into "Delayed start" mode. If you
enter time 00, this mode will not be activated. When the
"Delayed start" mode is already active, if you press the
"Timer" button again, you can correct the remaining
time in both possible directions. After setting the time,
the appliance goes into "Delayed start" mode with
the display showing the temperature and the hours
remaining until the appliance will switch to "Heating"
mode. You can exit this mode by pressing the "On/Off"
button. Then the convector will go into "Heating" mode.
The "Delayed start" mode can be set within a range from
01 to 96 hours.
Switching off "Heating" mode
You can exit "Heating" mode by pressing the "On/Off"
button. Then the heater will be switched off, and if it has
been on by then, the red LED will go out. The display will
continue showing the room temperature.
"Anti-frost function"
If the room temperature falls below 5 degrees Celsius
and the convector is off (the red LED is not lit, but the
mechanical switch is in position "I" (On)
be automatically switched on in order to prevent from
freezing.
English
and
you will enter
Enabling and disabling the anti-frost function:
"Temperature correction for the sensor" function
Due to the specifics of the temperature profile in some
premises there may be difference from the temperature
shown on the display and the actually measured
temperature in the various locations of the heating
appliance in the room.
or
buttons
user of the electric convector in the room which it is in. A
temperature difference greater than ±4 °C from the measured
temperature in a specific location in the room indicates that
the room where you use the convector in is not well insulated
or the temperature is not the same all around the room.
Example: a convector in a room on a stone floor – the
convector displays 18°С (the set temperature is 22°С), the
actually measured temperature (feeling of reached comfort
temperature) is 22°С at a height of 60 cm from the floor - >
in this case the convector continues to overheat the room
), the heater will
(this is a direct energy loss, but the convector cannot reach
the set temperature because it measures the temperature
at a low height close to the floor) and it will never switch
Entering a temperature correction for the
temperature sensor does not apply to this
function.
this function is enabled by default
to disable this function, the convector must be in
"Off" mode, when you press the
button for three seconds the display will show a
blinking "ON", and by pressing the
will reach the "OFF" position, then you need to wait
for 3 seconds and the function will automatically go
in "OFF" mode.
to enable this function again, the convector must
be in "Off" mode, when you press the
Off" button for three seconds the display will show
a blinking "OFF", and by pressing the
will reach the "ON" position, then you need to wait
for 3 seconds and the function will automatically go
in "ON" mode.
See the temperature shown on the display of the
appliance
Measure the temperature at a place where the
temperature is "comfortable" enough for you
(usually at a height of 60 cm from the floor, in
sitting positon). If you find a difference within a
range of ±4°С, you can set the necessary correction
in the convector's menu (It is important to
note that this function can be set only after the
temperature has become the same all around
the room, and depending on the room type, the
minimum required time is 7 hours) by entering
the temperature difference resulting between the
value on the display and the actually measured
temperature.
Note: This function is used with the purpose of providing
better temperature comfort and energy saving for the
Operation and Storage Manual