INSTALLATION MANUAL
1156CLA Co-Linear Adapter
CSA approved for use with Valor 200, 1100, 1150, 1400, 1500, 1700, 2500, and 2700
The 1156CLA Co-Linear adapter is a fi eld installed kit
to convert listed direct vent heaters from solid coaxial
venting to fl exible, side by side liners for co-linear
venting into existing solid fuel fi replaces and chimneys.
Co-linear piping can only be installed into solid-fuel
burning fi replace and chimney cavities.
Have the chimney swept and the fi replace cavity
including ash dumps and clean-outs cleaned before
installing the heater and vent liners. Any creosote or
soot residue remaining in the fi replace cavity chimney
or clean-out may cause odors or stains once the
heater is installed. Consult with chimney sweep for
information on how best to clean.
The 1156CLA may be fi tted to Valor heater models 200,
1100, 1150, 1400, 1500, 1700, 2500, and 2700.
Co-linear venting is for vertical termination only.
An approved co-linear terminal cap is required to
complete the termination of the co-linear chimney
system—see allowable venting accessories chart in
heater installation manual.
Notes:
• Venting limitations and restrictors are as per those
listed for coaxial venting in the heater installation
manual.
• Use gasketing supplied with this kit to ensure a good
seal. Gaskets can be held in place during assembly
by using a dab of silicone or white glue (wood / car-
penter's glue).
• Intake and exhaust liners must correspond between
heater and roof termination.
• Ensure liners do not sag and are not crimped when
installing.
• Do not bend liners less than 3" radius.
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
4004395-07
© Copyright Miles Industries Ltd., 2024
1156CLA
 WARNING
If the information in these instructions is
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
This kit must be installed or serviced by a
qualifi ed installer, service agency, or gas
supplier. These instructions are to be used
in conjunction with the main Installation
Manual for the heater it is installed on.
Kit Contents
1
4
3
#
Description
1
Air inlet box assembly
2
Intake box gasket
3
Adaptor tube (4" exhaust collar)
4
Adaptor tube gasket
5
2.5-4.5" hose clamp (2)
Conversion plate
#8 x 3/8" self-tapping metal screws (10)
2
5
Part Number
4004261
4004263
4004398
4001267
9800064
4000853

Publicité

loading

Sommaire des Matières pour Valor 1156CLA

  • Page 1 INSTALLATION MANUAL 1156CLA 1156CLA Co-Linear Adapter CSA approved for use with Valor 200, 1100, 1150, 1400, 1500, 1700, 2500, and 2700 The 1156CLA Co-Linear adapter is a fi eld installed kit to convert listed direct vent heaters from solid coaxial  WARNING...
  • Page 2 (Note: A 4” diameter collar and gasket supplied will adapter. Ensure all screws are tight. not be used for this application). The 1156CLA installs the same way on diff erent heaters. 1. Remove the 45-degree takeoff elbow and elbow gasket (6 screws). Keep the screws for re-use.
  • Page 3 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com...
  • Page 4 GUIDE D’INSTALLATION 1156CLA Raccord colinéaire 1156CLA Certifié pour usage avec foyers Valor 200, 1100, 1150, 1400, 1500, 1700, 2500 et 2700 Le Raccord colinéaire 1156CLA est utilisé au moment de l’installation du foyer pour le convertir d’une  AVERTISSEMENT évacuation coaxiale à une évacuation colinéaire à deux Si les instructions fournies dans le présent...
  • Page 5 (Note : Une buse de 4 po et joint d’étanchéité ne sont Assurez-vous que les vis soient bien serrées. pas utilisés pour cette application). Le 1156CLA s’installe de la même façon sur diff érents foyers. 1. Enlevez la buse d’évent 45 degrés et son joint d’étanchéité...
  • Page 6 Installation sur les foyers utilisant un 4. Placez le joint d’étanchéité de 4 po et la buse de 4 po sur la buse d’évacuation de 3 po. Fixez la buse à conduit d’évacuation de 4 po l’aide des 6 vis enlevées du raccord de sortie. 1.