MAJOR GENERATOR FEATURES
 Honda GX390 engine
 Cast-iron cylinder sleeve
 Low lubricant alert system
 Receptacles on control panel
 Cord Retainers
 Automatic voltage regulator (AVR)
 8 gallon metal fuel tank
 Analog Hour Meter
 Portability Kit
All manuals and user guides at all-guides.com
7
CONTROL PANEL
A. 120 V, 20 Ampere Duplex Receptacle
20 amps of current may be drawn from each half of the recep-
tacle. However, total power drawn must be kept within nameplate rat-
ings. These receptacles may be used along with the twistlock recep-
tacle provided the generator is not overloaded.
b. 120/240 V, 30 Ampere Twistlock Receptacle
A maximum of 30 amps may be drawn from the 120/240 volt
receptacle, provided it is the only receptacle used. However, current
must be limited to the nameplate rating. If the 120/240 volt receptacle
is used along with the 120 volt receptacle, the total load drawn must
not exceed the nameplate ratings.
C. Circuit breakers
The receptacles are protected by an AC circuit breaker. If the
generator is overloaded or an external short circuit occurs, the circuit
breaker will trip. If this occurs, disconnect all electrical loads and try
to determine the cause of the problem before attempting to use the
generator again. If overloading causes the circuit breaker to trip, re-
duce the load. NOTE: Continuous tripping of the circuit breaker
may cause damage to generator or equipment. The circuit breaker
may be reset by pushing the button of the breaker.
D. Cord Retainer
The cord retainer is used to prevent plugs from being pulled out
of the 120-volt receptacles.
E. Analog Hour Meter
A
E
120V AC/CA
Cord
Retainer
D
b
120V/240 AC/CA
120V AC/CA
NEUTRAL FLOATING
NEUTRAL FLOTAS
Cord
Retainer
C