Télécharger Imprimer la page

Emax Hulk HP02P010SS Mode D'emploi page 8

Publicité

Les langues disponibles

Les langues disponibles

HULK Power
Feet
Amp Rating
25
3-10 amp
18 ga.
10.1 - 12 amp
16 ga.
12.1 - 16 amp
14 ga.
Power Source Connection
Power Requirements
This tool is designed to operate on a properly
grounded 120 volt, 60 Hz, single phase alternating
current (AC) power source fused with a 15 amp time
delayed circuit breaker. It is recommended that a
qualified electrician verify the ACTUAL VOLTAGE at
the receptacle into which the tool will be plugged and
confirm that the receptacle is properly grounded. The
use of the proper circuit size can eliminate nuisance
circuit breaker tripping when using your tool.
Improper performance, and/or, damage to the tool
will result if operated on inadequate, or excessive
power.
DO NOT OPERATE THIS TOOL if
the ACTUAL power source
voltage is less than 105 volts AC or greater than
132 volts AC.
Grounding Instructions
In the event of an electrical malfunction or short
circuit, grounding reduces the risk of electric shock.
The motor of this machine is wired for 120 V single
phase operation and is equipped with a 3-conductor
cord and a 3-prong grounding plug to fit a grounded
A
B
fig 4
type receptacle (B, fig 4). Do not remove the 3rd
prong (grounding pin) to make it fit into an old 2-hole
wall socket or extension cord. If an adaptor plug is
used (C, fig 4) it must be attached to the metal screw
of the receptacle.
The use of an adaptor plug is illegal
in some areas, including Canada.
Check your local codes. If you have any doubts
or if the supplied plug does not correspond to
your electrical outlet, consult a qualified
electrician before proceeding.
Connect to power source
Consult a qualified electrician for proper installation
of receptacle at the source of power. This tool must
be grounded while in use to protect the operator from
electrical shock. If you are not sure if your outlet is
properly grounded, have it checked by a qualified
Total Extension Cord Length
Meters
Feet
Meters
8
50
15
16 ga.
16 ga.
12 ga.
Use only UL or CSA approved extension cords
electrician. Make sure the tool is turned OFF when
connecting the power cord to a properly grounded
120 Volts, 60 Hz, single phase, 15 amp power
source.
Getting Started
Unpack your compressor.
Before operating your tool, check the contents of the
box to make sure you have everything you will need.
Items included in the box:
repair.
Assembly
is turned off and unplugged from the power
supply.
Place compressor on level ground. It is designed to
function properly at an incline of no greater than 15
degrees.
Installing the air filter
The air filters should be installed into the tops of the
pump cylinder heads (as shown in fig 1, above).
1. Thread the air filter into motor head port located
C
2. Carefully screw each air filter into the cylinder
3. Be sure the short length of flexible hose is
Operation
Before operating your air compressor:
8
Feet
Meters
100
30
14 ga.
14 ga.
Not Recommended
● Air Compressor
● 2 Air Filters
● 2 Wheels
● Owner's Manual
Save packaging in case you need to
return the compressor for servicing or
Before performing any assembly or
maintenance, make sure compressor
under the plastic shroud.
head by turning the air filter clockwise, hand tight.
DO NOT over-tighten the air filter.
inserted into the hole in the air filter housing. This
increases the noise-reduction capabilities of your
compressor.
● Inspect for damage before using the air
compressor, make sure the air tank is not
damaged, inspect all parts for damage, and
check that all pipes and hoses are firmly
connected.
● Do not use the air compressor if any damage is
found. If damaged, have an authorized service
center inspect and test the air compressor to
ensure that is working properly.
Feet
Meters
125
40
14 ga.
14 ga.

Publicité