DPP240-xx-1
Product HANDBOOK
Special Safety Instructions:
Standard Specific Safety Instructions:
Whilst all individual outputs are classed as SELV outputs in accordance with the standard
IEC/EN/UL/CSA60950-1 (<60Vdc or 42.4V peak), seriesed combinations of these outputs may exceed these
values and become hazardous output voltages.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Environmental Specifications:
Description
Operation
Storage
Use
Indoor
-
Temperature
-25° C - +71° C (derating at 2.5%/° C from 61° C)
-25° C - +85° C
Humidity
20 - 95% RH, non-condensing
20 - 95% RH, non-
condensing
Altitude
2000m
4850m (IEC60068-2-13)
Orientation
See Fig 1
ALL
Material Group
IIIb
Pollution Degree
2
Class
I
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth: - 1500KVAC, 2121VDC
Primary mains circuits to secondary: 3kVAC, 4142VDC*
*This test is not possible with Y capacitors fitted to the unit as damage to these capacitors will occur. It is also
necessary to short circuit the output together and to earth.
Safety Approvals:
UL508
nd
UL/cUL60950-1 (2
Edition)
nd
IEC / EN60950-1(2
Edition)
CE marking when applied to any DPP240-xx-1 product indicates compliance with the Low Voltage Directive
nd
(2006/95/EC) in that it complies with EN60950-1 (2
Edition).
Fusing: Internal fuses (F1): Single fuse in the L line, T3.15AH, 250V, 5x20mm.
Symbols:
N
L
AC
EARTH
N – Neutral
L – Live
If the earth terminal of the DPP240-XX-1 PSU is connected to the main incoming earth conductor of the end
equipment, the installer must cover the earth symbol with a label bearing the earth symbol of IEC60417-5019.