NNS - 30 Instruction Manual
Items
1
Nominal Output Voltage
2
Maximum Output Current
3
Maximum Output Power
4
Efficiency (Typ)
5
Input Voltage Range
6
Input Current (Typ)
7
In-rush Current (Typ)
8
Output Voltage Range
9
Maximum Ripple & Noise
10 Maximum Line Regulation
11 Maximum Load Regulation
12 Over Current Protection
13 Over Voltage Protection
Crowbar Type
14 Remote Programming
15 Remote Sensing
16 Remote ON/OFF Control
17 Parallel Operation
18 Series Operation
19 Operating Temperature
20 Operating Humidity RH
21 Storage Temperature
22 Storage Humidity RH
23 Cooling
24 Temperature Coefficient
25 Withstand Voltage
26 Insulation Resistance
27 Vibration
28 Shock
29 Weight
30 Size (W*H*D)
31 EMI
32 Regulatory Agency
NOTES
* 1: At 100VAC and maximum Output Power.
* 2: For cases where conformance various safety specs. (UL, UL-C, TUV, etc.) are required, input voltage will be 250VAC max.
and frequency range 47~ 63Hz.
* 3: Floating output or grounded +V or -V Terminal.
* 4: Foldback current limit with automatic recover for each output.
* 5: See Otltline Drwings.
* 6: For each output - OVP circuit will shut down output, manual reset. (Line recycle)
IMPORTANT,
See Installation Instructions Before Connecting to the Supply.
Dwg. No.
Model
NNS 30-5
NNS 30-12
V
5
A
6
W
30
(*1)
%
35%
100: 85~115VAC
(*2)
-
200: 170~230VAC 230: 195~265VAC
(*1)
A
1.14
A
20A@ 100VAC 10A@ 200VAC, cold start
%
(*3)
mV
mV
0.5mV
mV
1.5mV
(*4)
A
6.30~7.80
4.20~5.20
(*6)
V
6.0~7.2V
14.5~17.2V
-
Volt/Volt, 1000Ω / Volt typ. +S to +LS Terminals
-
Possible, Via +S, -S Terminals
-
-
Possible, current sharing with single connection VIA PC terminal
-
Possible
°C
-20~71°C, -20°C...60%, 0~50°C...100%, 60°C...60%, 71°C...40%
%
°C
%
-
(*1)
-
-
Input-Output...3.75K VAC Input-Chassis...2.5K VAC for 1 min. @ 20mA
-
More than 100M Ω at DC 500V @25°C and 70% RH for 1 min.
-
10~55Hz Amplitude (sweep 1 min.) less than 2G X, Y, Z 1h. each
-
gm
(*5)
mm
-
Designed to meet EN55022-1, CISPR-22, FCC Part 15, VCCI-class B
-
Designed to meet IEC/EN/UL 60950-1 Ed.2
1
IA501-04-01H
NNS 30-15
NNS 30-24
12.0
15.0
24.0
4.0
3.4
2.3
48
51
55.2
45%
46%
50%
115: 98~132VAC
47~440Hz
1.41
1.47
1.45
+/- 10
1mV RMS 3mV ptp
1.2mV
1.5mV
2.4mV
3.6mV
4.5mV
7.2mV
3.57~4.42
2.42~3.00
18.1~21.5V
29.0~34.3V
N.A.
30~95%
-40~85°C
10~95%
Convection Cooling
0.02% / °C
Less than 20 G
2930
80 x 124 x 178
NNS 30-48
48.0
1.1
52.8
54%
1.35
4.8mV
14.4mV
1.15~1.43
58.1~68.6V