2. OPERATING INSTRUCTIONS
2.1
GENERAL
Operation of the Model 5U1000 broadband amplifier is quite simple. The input signal, whether swept of fixed
in frequency, is fed into the jack marked INPUT and the amplifier output signal is taken from the jack labeled
OUTPUT. The unit is turned on by activating the power switch marked 0, 1. In the event of a unit malfunction,
protection is provided by fusing located at the rear of the unit. A polarized, three (3) wire AC power cord is
also included with the unit to provide cabinet and chassis grounding to the power mains.
2.2
AMPLIFIER OPERATION
Figure 2-1 shows the front view of the Model 5U1000 amplifier.
Rev A
The Model 5U1000 amplifier is not critical in regards to source and load
VSWR and will remain unconditionally stable with any magnitude and
phase of source and load VSWR. It also has been designed to withstand,
without damage, RF input power up to twenty (2) times its rated input of
1mW: However, signal levels higher than 20 mW or transients with high
peak voltages can damage the amplifier. Also, accidental connection of the
5U1000 output to the input cause oscillation which will permanently
damage the input transistor.
Figure 2-1. Amplifier Front View
Figure 2-2. Amplifier Back View
CAUTION:
5