5. TECHNICAL CHARACTERISTICS
Absorbed ladings and dimensions
The absorbed power, the external and internal dimensions for the various
models and in various configurations are shown in the table from chapter
11.
Noise and vibration
The sound level of the equipment fitted with integral hermetic condensing
unit does not exceed 70dB. Under normal conditions the equipment does
not generate vibrations that affect the surroundings.
The appliance is designed to be used below the max temperature and
humidity indicated in the table 3 (technical characteristics). The use
of the appliance at temperatures and/or humidity higher than the
specified ones may lead to poor work performances and/or
unexpected failures.
6. USE
Activation
These cabinets are activated by an electronic control panel. The operations
available to the user are:
Startup/shutdown of the unit
Put the plug into the power socket. To disconnect the cabinet, unplug it
from the power socket. In case of power supply interruption, the
compressor will normally restart with a slight delay.
Setting the cell temperature (fig. 1)
Press the SET key for three seconds to enter the settings menu (the "set"
light lights up and the display shows "St").
Press once the SET key: the display shows the actual set temperature.
To change the set temperature, press the
(DOWN) to increase or decrease the set temperature until it reaches the
new desired temperature.
Press the RST key or do not press any key for 30 seconds to save the new
value and exit the settings menu.
WARNING:
Never set a temperature different from the following:
Models R – R S/S – RG: between +2 and +10 °C
-
Models F – F S/S: between -18 and -22 °C
-
Setting different temperatures from these may lead to irreversible
damage for the appliance !!!
Visualization of alarm codes
The display may show the following error code:
-
E1 = temperature probe defective or disconnected.