Choose one option to attach duct connector.
1 3
New Construction
Install duct connector (use screw from parts bag
and ensure tabs engage in housing), then attach new
construction ductwork with foil tape.
Pro Tip: First and last 18" of the ducting should be rigid or stretched straight for expected performance.
Connect wiring.
1 4
2-
TO
FUNCTION
WALL CONTROL
Black
(Hot/Switched)
White (Neutral)
Ground (Green/Copper)
Red (Hot/Switched)
Attach wire enclosure by tab and screw.
1 5
TABS
FOIL TAPE
Pull ductwork into housing and attach to duct connector
with foil tape, then install duct connector (use screw from
parts bag and ensure tabs engage in housing).
FOIL TAPE
or
Re-install wiring panel and secure with screw
1 6
from parts bag.
3
Retrofit
TABS
Scan this QR code for
helpful hints.