1. Use this unit only in the manner intended by the manufacturer. Contact the manufacturer in case of questions
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switching on
accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities
5. When cutting or drilling into wall or ceiling, DO NOT damage electrical wiring and other hidden utilities
6. Ducted fans MUST always be vented to the outdoors
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) —protected branch circuit (ceiling installation only)
8. To reduce risk of fire and to properly exhaust air, be sure to duct air outside — DO NOT vent exhaust air into spaces within walls or ceilings or
into attics, crawl spaces, or garages. This fan is NOT for use in kitchens
9. DO NOT use this fan with any solid-state speed control device
10. The fan MUST NOT be installed in a ceiling thermally insulated to a value greater than R40
11. This unit must be grounded
CAUTION
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.
Electrical products can cause death or injury, or damage to property.
If in any doubt about the installation or use of this product, consult a competent electrician.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance — lower or remove grille and vacuum interior of unit
with the dusting brush attachment. The motor is permanently lubricated and never needs oiling. If the motor bearings are
making excessive or unusual noises, replace the motor with the exact service motor. The impeller should also be replaced.
OPERATION
Use an on/off switch to operate this fan. See "CONNECT ELECTRICAL WIRING" for details.
Installer: Leave this manual with the homeowner.
info@ortechindustries.com
www.ortechindustries.ca
WARNING
WARNING — THE INSTALLATION MUST BE CARRIED OUT BY
A QUALIFIED ELECTRICIAN.
1. For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and vapours
2. This product is designed for installation in ceilings up to a 12/12 pitch (45º).
Duct connector MUST point up. DO NOT mount this product in a wall
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit
4. Read specification label on product for further information and requirements
Application Notice
READ AND SAVE THESE INSTRUCTIONS
13376 Comber Way
Surrey BC V3W 5V9
205 Summerlea Rd
Brampton, ON L6T 4E5
Instruction Manual
1-888-543-6473
1-888-541-6474

Publicité

loading

Sommaire des Matières pour Ortech Universal Serie

  • Page 1 Universal Series Instruction Manual MODEL OD-9005PB | OD-1109PB | OD-1209PB | OD-1505PB WARNING WARNING — THE INSTALLATION MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN. 1. For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and vapours 2.
  • Page 2 Universal Series Instruction Manual MODEL OD-9005PB | OD-1109PB | OD-1209PB | OD-1505PB INSTALLATION 1. Do not use in a cooking area. 2. Two ways to connect ductwork to a factory-shipped unit. INSULATION* ROOF CAP* (Place around and (with built-in over Fan Housing.) damper) POWER HOUSING...
  • Page 3 Universal Series Instruction Manual MODEL OD-9005PB | OD-1109PB | OD-1209PB | OD-1505PB WIRING WIRING Run 120 V AC house wiring to the location of the fan. Use only UL- approved connectors (not included) to attach the house wiring to the wiring plate.
  • Page 4 Série universelle Instruction Manual MODÈLE OD-9005PB | OD-1109PB | OD-1209PB | OD-1505PB AVERTISSEMENT AVERTISSEMENT - L'INSTALLATION DOIT ÊTRE EFFECTUÉE PAR UN ÉLECTRICIEN QUALIFIÉ. 1. Pour une utilisation générale de ventilation uniquement. NE PAS utiliser pour évacuer des matériaux et des vapeurs dangereux ou explosifs. 2.
  • Page 5 Série universelle Instruction Manual MODÈLE OD-9005PB | OD-1109PB | OD-1209PB | OD-1505PB INSTALLATION 1. Ne pas utiliser dans une zone de cuisson. 2. Il existe deux façons de raccorder un conduit à un appareil livré en usine. Instructions d'assemblage 1. Des barres de suspension coulissantes ont été prévues, qui permettent de Hanger Bar positionner le boîtier avec précision à...
  • Page 6 Série universelle Instruction Manual MODÈLE OD-9005PB | OD-1109PB | OD-1209PB | OD-1505PB CÂBLAGE Relier le circuit électrique de votre maison de 120 V c.a. à l’emplacement du ventilateur. Utilisez seulement des raccords homologués par UL pour relier le circuit électrique de votre maison à la plaque de câblage. Branchez les fils comme illustré ci-dessous. NOIR (BLK) BLANC (WHT) MISE À...

Ce manuel est également adapté pour:

Universal od-9005pbUniversal od-1109pbUniversal od-1209pbUniversal od-1505pb