TECHNICAL DATA
Power supply
Maximum
absorbed
power
Microwave power
Grill
Hot air
Microwave frequency
Electrical Hook-Up
Before making the electrical hook-up, make sure that:
• the characteristics of the electrical system satisfy what is
shown on the serial number plate applied to the front of
the oven;
• the electrical system has an effect earth connection
conforming to standards and current law.
The earth connection is required by law.
The cable must not, at any point, reach a temperature
greater than 50 °C above the ambient temperature.
This oven must be connected to the supply by a supply cord
fitted with an appropriately rated plug that is compatible
with the socket-outlet fitted to the final sub-circuit in the fixed
wiring that is intended to supply this oven.
If a fixed appliance does not have a power cord and plug,
or another device that ensures disconnection from the
mains, with an opening distance of the contacts that allows
complete disconnection under the conditions of excessive
voltage category III, such disconnection devices must be
provided in the power supply mains conforming to the
installation rules.
The omnipolar socket or switch must be easy to reach when
the appliance is installed.
NOTE: The manufacturer declines all liability if the usual
accident prevention standards and the above
instructions are not followed.
220-240 V~,
50
Hz
3200
W
900
W
1500
W
1500
W
2450 MHz
TYPE AND MINIMUM DIAMETER OF THE CABLES
H05RR-F
3x1,5 mm²
H05VV-F
3x1,5 mm²
H05RN-F
3x1,5 mm²
H05V2V2-F
3x1,5 mm²
SASO
H05RR-F
3x2,5 mm²
H05VV-F
3x2,5 mm²
H05RN-F
3x2,5 mm²
H05V2V2-F
3x2,5 mm²