Télécharger Imprimer la page

SECU FALZ 2.0 Instructions De Montage page 2

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Assembly instructions
FALZ 2.0 – standing seam roof
®
SECU
Anchor device Type A according to DIN EN 795:2012 and DIN CEN/TS16415:2017 for securing personal fall protection equipment.
PRELIMINARY REMARKS
Before installing the temporary anchor construction SECU
checked. The technical building regulations must be observed. Loads of up to 6 kN can occur at the single anchor point.
Attention!
®
The SECU
FALZ 2.0 anchor device must not be used as a lifting eye or for attaching loads. Only original parts of the SECU
FALZ 2.0 system must be used. Assembly may only be carried out by qualified personnel. These installation instructions and
the SKYLOTEC safety instructions must be read and understood.
ASSEMBLY
®
1. Place the SECU
FALZ 2.0 on the standing seam from above so that the grub screw is screwed into the
back of the rebate.
2. Tighten the grub screws with a tightening torque of 15-17 Nm.
Requirements
• Sheet thickness
• Material:
• Adhesion:
®
The SECU
FALZ 2.0 may potentially obstruct the thermally induced length changes of the sheet if, despite the high
clamping point of the clamps, the foot of a sliding clip extends into the clamping area of the clamp. In such cases, the
®
SECU
FALZ 2.0 should be positioned so that the sliding clip is centered beneath the SECU
The correct positioning of the seam clamps on the standing seam profile must be checked before each use of the
temporary anchor device!
SKYLOTEC GmbH | Im Mühlengrund 6-8 | 56566 Neuwied | Tel +49 (0) 2631 - 9680-0 | info@skylotec.de | www.skylotec.com
For clamping onto standing seam roofs
®
FALZ 2.0, the load-bearing capacity of the roof construction must be
min. 0.7mm
aluminum, titanium zinc, and steel, stainless steel
min. 50mm
®
FALZ 2.0.