INSTRUCTION MANUAL
Capillary thermostat series TKR100
Description and use
Capillary thermostats are designed for thermoregulation in appliances heated up by
alternate electric current (boilers, etc.) Thermostat do not serve as a breaker.
Thermostat is supplied with change-over contacts, you can choose from desired
function: switch on or switch off. Required temperature can be set by shaft
(regulatory knob shaft shoulder optional) model TKR 100
Design
Instalace
Installation
Instalace
Warning:
Installation and connection of the controller to the electrical circuit may only be
performed by a person with a qualification of min. according to Decree No.
50/1978 §6, or a professional service worker. The following recommendations
must be followed during installation:
• Only install the controller in devices intended for this purposeoperating
instructions (Class I appliances) so thatthe connection terminals are under a non-
removable cover.
• Connect the terminals to the electrical circuit and the grounding pin using 6.3 x
0.8 mm sockets according to ČSN EN 61210.
• Bend the capillary with a minimum radius R = 5 mm.
• Select the length of the M4 fastening screws so that they do not interfere with the
switching device after tightening, tighten the screws to a torque of 1.2 Nm to the
controlpanel or beam.
• The switch head may be mounted in room snormal environment AB5, AE1, AM1,
AN1, Be1,
Storing conditions
Instalace
Storing can be done in closed and aired rooms within temperature range
15–60 °C. Storing and trasfer must not cause a mechanical damage of the
device. Capillary thermostat must be treated with care, with no major shocks or
vibrations.
Instalace
Disposal
Disposal should be performed as follows: Hand into a recycling collection
point.
Instalace
Warranty
Provided, that the product has been placed and used according to the
instruction manual, the manufacturer provides with warranty in compliance
with a valid code, unless agreed otherwise.
The manufacturer will reject warranty repair, in case the product has been
damaged:
during tranport and storage of the purchaser, or his customers,
-
during installation or disassembly of device of the purchaser or his
-
customer.
Warranty and post-warranty repairs
Instalace
Warranty and post-warranty repairs are provided by the manufacturer. Warranty
claim of a faulty thermostat should be done at the seller. The warranty claim will be
accepted in case, that following requirements are met:
submitted warranty list of the given thermostat,
-
paid invoice of the thermostat,
-
the conditions and requirements of operating manual were met.
-
Instalace
Wiring diagram
Certificate of conformity:
For evaluation of conformity was used protocol nr.6450-004/2009
Harmonized norms: ČSN EN 61010-1:2003, ČSN EN 60695-2-11:2001
Technical parameters
Typ
e
Regula
tor range
Setting accuracy
Dif erence
f
Max. sensor temperature
Capillary length
A gular setting
n
Case
galvanized sheet
Sensor
Capillary
copper with
Contact load
16(4)A, 250V; 6(1)A, 400V
TKR 100
7-77°C
±
5°C
±
3 1°C
120°C
1000 mm
270°C
/ plast
ic
copper
PVC
protection