1. INTRODUCTION
Thank you for acquiring the heat pump for heating outdoor swimming pools. The experience our company has gained during more
than 20 years in the world of air conditioning of swimming pools has been put to your service in this product, in which we also incor-
porate the technical breakthroughs that turn this heat pump into the equipment that can solve once and for all the air conditioning
of your swimming pool, extending thus the length of your bathing season.
We kindly request the client or installer to read this manual carefully in order to:
Be familiar with all the potentialities of the unit and to take into account all the necessary circumstances for
Dealer's stamp
2. ADDITIONAL RECOMMENDATIONS.
A. Installation and maintenance
- In the event of any intervention in the unit, installation, start-up or maintenance, the personnel in charge of these operations must
be familiar with both the instructions and recommendations contained in the installation manual and the elements of the project. -
The personnel in charge of the receipt of the unit will perform a visual inspection in order to verify the possible damages suffered in
the transport: refrigeration circuit, electrical cabinet, frame and housing.
- It is prohibited to place the unit near:
• Heat sources • Flammable materials • Building air intakes
- The unit must be installed, started-up, repaired and maintained by qualified personnel according to applicable regulations and
laws.
- During installation, repairs and maintenance piping should not be tread on or used as a support, otherwise the piping could break
R407C
and the
gas could cause severe burns.
- During maintenance of the unit, the composition and state of the gas will be revised as well as possible oil stains (leaks in the
refrigeration circuit).
- During the annual maintenance revision of circuit water tightness according to regulations, verify that the high-pressure and low-
pressure controllers are properly connected to the refrigeration circuit and that they switch off the electrical circuit in case of failure.
- In the event of any manipulation or intervention on the refrigeration circuit, it is obligatory to switch off the unit and wait several
minutes before puncturing pressure gauges or measuring temperatures. Some elements such as the compressor and pipes can
reach high temperatures and high pressures that can lead to important burns.
IMPORTANT
Complete a correct installation and start-up.
its correct and lasting operation.
Pressure Equipment Directive (PED-97/23/EC)
PacECO HEAT PUMP
Installer's stamp
27