Possible Problem
The hood is not venting
out properly.
The unit turns on by
itself.
Filter is vibrating.
The speed levels of the
blower sound the same.
RF Remote control does
not work.
Siena Pro Island Use, Care, and Installation Guide
Possible Cause
Using the wrong size of ducting.
The hood might be hanging to high
from the cook top.
The wind from the opened windows
or opened doors in the surrounding
area are affecting the ventilation of
the hood.
Blockage in the duct opening or
ductwork.
Remote control may be paired
incorrectly.
Filter is loose.
Spring clip is broken on the filter.
Using the wrong size of ducting.
Battery is dead.
Poor communication with the hood.
RF Remote lost communication with
the hood.
Blue antenna wire is not extended.
Troubleshooting
Solutions
Change the ducting to the correct size.
Adjust the distance between the cook top
and the bottom of the hood within 24" and
34" range.
Close all the windows and doors to eliminate
the outside wind flow.
Remove all the blocking from the duct work
or duct opening.
Resynchronize the remote control to
connect to a different channel
Adjust or change the filter.
Change the spring clip.
Change the ducting to at least 10" or higher.
Replace battery with type A23 12v.
Remote control must be within 15 ft of hood.
Reset hood and remote by switching power
off at the circuit breaker for 5 minutes.
Place remote on counter top near the hood
and switch the circuit breaker back on.
Extend the blue antenna wire behind the
light panel.