Guarantee
Your product
is guaranteed
for one year from the date of
original purchase, or hire purchase, against defects in materials
or workmanship
during
manufacture.
Within
the guarantee
period we undertake at our discretion, to repair or replace free
of charge to the purchaser,
any part found to be defective,
subject to the following conditions:
CONDITIONS
1. Claims made under the terms of the guarantee
must be
supported
by the original invoice/bill of sale issued at the
time of sale, or the machine Serial No.
2. For claims under this guarantee
contact the supplier from
whom you purchased
the product who will arrange
the
appropriate action. Do not initially return the product as this
could result in transit damage.
3. Neither Truvox
nor its distributor
shall be liable for any
incidental or consequential
loss.
4. This guarantee is governed by the laws of England.
5. This guarantee does not cover any of the following:
Periodic maintenance,
and repair or replacement
of
parts due to normal wear and tear.
Recommended Spares
&
Accessories
Damage caused by accident,
misuse or neglect, or
the fitting of other than genuine Truvox parts.
Defects in other than genuine Truvox parts, or repairs,
modifications
or adjustments
performed by other than
a Truvox
service
engineer
or authorised
service
agent.
Costs
and
risks
of transport
relating
directly
or
indirectly to the guarantee of this product.
Consumable
items such as, brushes,
drive discs,
filters and vacuum skirts.
• This guarantee does not affect your statutory rights, or your
rights against the supplier arising from their sales or
purchase contract.
Truvox's policy is one of continual
product development and we reserve the right to alter
specifications without prior notice.
Part No.
Item
05-4741-0000
HEPA Media vacuum bags
0014-0814
Vacuum belt Pack of 2
C223-2400
Charger including UK & EURO cables
Fault diagnosis
The following simple checks may be performed by the operator:
Trouble
Reason
Remedy
Machine not
• Battery pack has not been placed
• Ensure the battery pack is fitted
working
properly in the battery holder
correctly
• Battery empty
• Charge the battery
• Mains switch on the battery is in the off
• Switch to on position
position
Battery pack is
• Lack of voltage/electrical
supply
• Check fuse *, supply cord, plug
not charging
and socket outlet
Loss of suction
• Bag full
• Replace bag
• Broken belt
• Replace belt
• Worn brush roll
• Replace brush roll
• Contact supplier
Charger's LED
• Check the power cable and the
indicator is off
&
power plug of the device.
no output voltage
when plugged in
Dust escaping
• Vacuum bag not installed correctly
• Install bag properly.
from vacuum
* If the fuse blows several times, the machine should be checked by an authorises Service Agent