Installation & Operation Manual
The Merlin 1000S gas pressure proving system is designed specifically for use in educational establishments and
laboratories. The system is designed to give full control over incoming gas supply with the lockable main key-
switch.
The information contained within this manual should be referenced for typical installation and operation only.
For specific requirements that may deviate from the information in this guide – contact your supplier.
Rev: 1
01-21
Merlin 1000S
Gas Isolation Controller

Installation & Operation Manual
Please read this manual carefully and retain for future use.
Merlin 1000S
1

Publicité

loading

Sommaire des Matières pour CGS Merlin 1000S

  • Page 1 Please read this manual carefully and retain for future use. The Merlin 1000S gas pressure proving system is designed specifically for use in educational establishments and laboratories. The system is designed to give full control over incoming gas supply with the lockable main key- switch.
  • Page 2 Installation & Operation Manual Merlin 1000S Contents IMPORTANT WARNING STATEMENTS ............3 Installation ....................4 Planning ........................4 Fixing - Mounting ......................4 Typical Installation Arrangement ................. 5 Terminal Connections ....................5 Switch Settings ......................7 General Specification ....................8 Operation ....................
  • Page 3 Please contact your supplier or local authority for details of recycling schemes in your area. Alternatively, all CGS products can be securely packaged and returned clearly marked for disposal. Rev: 1 01-21...
  • Page 4 This panel is to be used to carry out a gas-proving test on the pipe work in order to highlight if there is a gas appliance open or a gas leak in a laboratory. The Merlin 1000S is designed to give the teacher full control over the incoming gas supply with the lockable main key-switch.
  • Page 5 Installation & Operation Manual Merlin 1000S Typical Installation Arrangement Terminal Connections 1. POWER / LINE IN 110-120V AC Power should be supplied to the [POWER / LINE IN] terminal and fused at 3A. 2. GAS SOLENOID VALVE OUTPUT 110-120V AC electrical power supplied from the [VALVE OUT] connector using a 3 core cable can be connected to a gas solenoid valve which can shut the gas supply on alarm status.
  • Page 6 Connections for remote emergency shut-off or stop buttons is detailed on the circuit board as [EM REMOTE]. This is linked out as a factory setting. Remote emergency shut-off buttons should be volt free and wired to the Merlin 1000S using a plenum security cable, white, 18/2 (18AWG 2 conductor), stranded, CMP or similar.
  • Page 7 Installation & Operation Manual Merlin 1000S Switch Settings Auto Reset When power is restored after the power cut/ loss, the panel has to be restarted manually. (Default) This will instruct the system to restart automatically when power is restored after power cut/loss.
  • Page 8 Fire Panel Integration The Merlin 1000S can be integrated with a fire alarm to close the gas supply automatically in the event of a fire. The volt free fire alarm signal can be wired in series with any remote emergency shut off buttons.
  • Page 9  Gas On When the key switch is turned on, the Merlin 1000S will check the installation for gas leaks. If gas proving is successful, the gas valve will open and the ‘Gas On’ LED will illuminate. ON = Gas On OFF = Gas Off ...
  • Page 10 Installation & Operation Manual Merlin 1000S  Timeout Under normal working conditions this LED is off. This LED will illuminate AMBER when auto-shut down has occurred. OFF = OK ON = Auto-shut down activated.  EM Stop If an emergency shut off button (either remote or on the panel) is pressed, the LED will illuminate AMBER and the gas will be turned off.
  • Page 11 What equipment do I need to perform a Bump Test? Contact your CGS representative for details of suitable bump testing kits and gases. Kits usually consist of a certified gas cylinder; flow control regulator, tube pipe and applicator cone.
  • Page 12 Installation & Operation Manual Merlin 1000S Installation Details Please pass this manual to the system owner or system user. Date of Installation: Installation Location: Organisation: Stamp/ Signature of the installer:   Canadian Gas Safety info@canadiangassafety.com Telephone: 647-577-1500 Canadian Gas Safety is the owner of this document and reserves all rights of modification without prior notice.
  • Page 13 Veuillez lire attentivement ce manuel et le conserver pour une utilisation ultérieure. Le système Merlin 1000S d’essai de la pression du gaz est conçu spécifiquement pour une utilisation dans les établissements d'enseignement et les laboratoires. Le système est conçu pour permettre un contrôle total de l'alimentation en gaz.
  • Page 14 Manuel d'installation et d'utilisation Merlin 1000S Table des matières MISES EN GARDE IMPORTANTES ................3 INSTALLATION ......................4 Planification ..........................4 Fixation - Montage ........................4 Disposition typique d'installation ....................5 Connexions des terminaux ......................5 Réglages interrupteurs ........................ 7 Spécification générale .........................
  • Page 15 Veuillez contacter votre fournisseur ou votre autorité locale pour obtenir des détails sur les programmes de recyclage dans votre région. Sinon, tous les produits CGS peuvent être emballés en toute sécurité et retournés clairement marqués pour être éliminés. Rév : 1...
  • Page 16 évidence si un appareil à gaz est ouvert ou s'il y a une fuite de gaz dans un laboratoire. Le Merlin 1000S est conçu pour donner au professeur le contrôle total de l'alimentation en gaz. Le Merlin 1000S peut fonctionner en conjonction avec des capteurs de dioxyde de carbone, de gaz naturel, de monoxyde de carbone et de GPL.
  • Page 17 Manuel d'installation et d'utilisation Merlin 1000S Disposition typique d'installation Connexions des terminaux 1. POWER/LINE IN L'alimentation 110-120 V CA doit être fournie à la borne [POWER / LINE IN] et être protégée par un fusible de 3 A. 2. VALVE OUT Une alimentation électrique de 110-120 V CA fournie par le connecteur [VALVE OUT] à...
  • Page 18 [EM REMOTE]. Il s'agit d'un réglage d'usine. Les boutons d'arrêt d'urgence à distance doivent être libres de potentiel et reliés au Merlin 1000S par un câble de sécurité de plénum, blanc, 18/2 (conducteur 18AWG 2), toronné, CMP ou similaire.
  • Page 19 Manuel d'installation et d'utilisation Merlin 1000S Réglages interrupteurs Réinitialisation automatique [AUTO RESET]. Lorsque le courant est rétabli après la coupure/la perte de courant, le panneau doit être redémarré manuellement. (Par défaut) Le système redémarrera automatiquement lorsque le courant sera rétabli après une coupure/perte de courant.
  • Page 20 Merlin 1000S Intégration du panneau incendie Le Merlin 1000S peut être intégré avec une alarme incendie pour fermer automatiquement l'alimentation en gaz en cas d'incendie. Le signal d'alarme d'incendie sans tension peut être câblé en série avec n'importe quel bouton d'arrêt d'urgence à distance. Si aucun bouton d'arrêt d'urgence à distance n'est installé, branchez-le directement sur le terminal marqué...
  • Page 21  Gaz sur Lorsque l'interrupteur à clé est activé, le Merlin 1000S vérifie l'installation pour détecter les fuites de gaz. Si la vérification du gaz réussit, la vanne de gaz s'ouvre et la LED «Gas On» s'allume. ON = Gaz sur OFF = désactivé...
  • Page 22 Manuel d'installation et d'utilisation Merlin 1000S  Temps d’arrêt Dans des conditions de travail normales, cette DEL est éteinte. Cette DEL s'allume en couleur AMBRE lorsque l'arrêt automatique a eu lieu. OFF = OK ON = Arrêt automatique activé. ...
  • Page 23 De quel matériel ai-je besoin pour effectuer un test de déclenchement? Contactez votre représentant CGS pour obtenir des détails sur les kits de tests de déclenchement et les gaz appropriés.
  • Page 24 Manuel d'installation et d'utilisation Merlin 1000S Détails de l'installation Veuillez transmettre ce manuel au propriétaire ou à l'utilisateur du système. Date d'installation : Lieu d'installation : Entreprise : Cachet / Signature de l'installateur :   Canadian Gas Safety info@canadiangassafety.com Téléphone : (647) 577-1500...