7.
Troubleshooting
The appliance does not
work.
Significantly reduced
airflow.
Poor purification quality.
The reset button lights
after filter replacement.
8.
Technical Specifications
power supply ............................................................................. 220-240 V~, 50 Hz
power consumption ........................................................................................ 60 W
wireless frequency ......................................................................... 2.412-2.484 GHz
max. RF power transmitted ........................................................................... 63 mW
maximum room size ..................................................................................... 70 m²
noise level ................................................................................................. < 46 dB
timer .................................................................................................................. -
fan speed settings ............................................................................................... 4
filter type ............................................................... pre-filter + EPA12 (carbon filter)
air purifier capacity ...................................................................................350 m³/h
material ........................................................................................................ HIPS
colour ...........................................................................................................white
dimensions .............................................................................. 445 x 350 x 220 mm
weight ....................................................................................................... 5800 g
cord length ................................................................................................... 1.8 m
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulting from (incorrect) use of
this device. For more info concerning this product and the latest version of this
manual, please visit our website www.velleman.eu. The information in this
manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights
reserved. No part of this manual may be copied, reproduced, translated or reduced to
any electronic medium or otherwise without the prior written consent of the copyright
holder.
V. 01 – 24/08/2020
Problem
AIRP002
Cause
The appliance is not
connected to the mains.
The appliance is not
switched on.
The filter packaging has
not been removed.
Low fan speed.
Dirty filter.
Not enough clearance
around the appliance.
The room is too large.
Blocked air inlet or outlet.
The filter is not properly
installed.
The appliance has not been
reset.
7
Possible solution
Connect the appliance
correctly to the mains.
Press the on-off button
once.
Remove the filter
packaging before use.
Select a higher fan speed
with the speed button.
Replace the filter.
Ensure at least 0.5 m of
clearance around the
appliance.
Only use the appliance in
rooms smaller than 8 m².
Remove all objects
blocking the air inlet or
outlet.
Make sure the filter is
properly installed.
Press and hold the reset
button for 5 seconds to
reset the appliance.