10. Troubleshooting guide
Faults
Motor fails to start
up
No intake
Inadequate delivery
rate
Thermostat swit-
ches pump off
Anl_GE_WW_5537_E_SPK1.indb 22
Anl_GE_WW_5537_E_SPK1.indb 22
GB
Cause
- No mains voltage
- Pump rotor blocked -thermostat
switched off
- Non-return valve dirty
- Pump chamber without water con-
nection
- Air in intake line air-tight
- Max. suction height exceeded
- Suction height too high
- Coarse fi lter dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
- Motor overloaded - friction caused
by foreign substances too high
- 22 -
Remedy
- Check voltage
- Dismantle and clean pump
- clean
- Fill water into intake
- Make sure intake line is close
- Check suction height
- Check suction height
- clean
- Place the suction hose at a deeper
level
- Clean pump and replace wearing
- Dismantle and clean pump. Prevent
intake of foreign substances (fi lter)
07.11.12 16:45