Télécharger Imprimer la page

DOLD RX11M/K Traduction De La Notice Originale page 20

Publicité

Les langues disponibles

Les langues disponibles

Design and Function
Attention!
Hazards must be ruled out before the movable part of the
!
guard can then be opened! and the dangerous location can
be reached!
The STS/K key exchange unit is to be integrated into a system and
connected with a control unit so that the hazardous machine can run only
when the guard is locked and closed.
The second key can be removed after entering a first key. The first key is
blocked and the third key released after removing the second key. The first
key can only be removed again after the third and then the second key
were returned to their starting position.
RX11M/K is used in the system in connection with additional STS/K
units and SAFEMASTER products. The first key to be entered may
originate from these units (e.g. release through upstream solenoid locking
ZRH01BM/K in connection with a speed monitor UH 5947 or standstill
monitor LH 5946). The second key to be removed can serve as
protection against lock-in or for the operating release of additional units
(e.g. M10BM/K, M11BM/K, M12M/K, M10B01M/K). The first key can be
assigned to a person with access rights.
Indications
LED red/green
Separately controllable
Circuit Diagrams
3
14
2
11
12
1
9
22
11
21
24
10
7
32
8
31
4
red
5
green
6
12
M9895_b
Fig. 1:
Locked while activated:
1st key removed (bottom)
2nd key inserted (top)
20
3
14
2
11
12
1
9
22
11
21
24
10
7
32
8
31
4
red
5
green
6
12
M10174
Fig. 2:
Lock deactivated:
1st key inserted (bottom)
2nd key removed (top)
RX11M/K
Mechanical Switch
Positions
Circuit Diagram
3
2
3
1
9
10
9
11
7
8
closed
open
SAFEMASTER STS/K-RX11M/K / 11.01.21 en / 335A