GAS COMPONENT CONNECTION CHECKS
Thermocouple
3. Make sure that the igniter pin and thermocouple are correctly positioned.
- The igniter pin should be pointed straight to the thermocouple.
- The thermocouple should be positioned 5mm / 0.196" away from the burner tube.
Thermocouple
Wire
4. Make sure that the thermocouple wire is correctly positioned. The thermocouple
wire should be in line with the valve.
5mm /
0.196"
Valve
Igniter Box
Burner pots
Igniter Pin
Thermocouple Wire
16 / 60
Wire should
be in line
with valve
Valve