Requirements | Assembly instructions | Care information
Read
all
safety
cause serious injury.
Observe the local building regulations as well as the snow load zones in your region.
Open fire, highly flammable substances or the like are not permitted underneath the product. Escape routes must
be available and kept clear.
Sort the parts before assembly and check the contents list according to the assembly instructions.
At least 2 persons are required to assemble the patio roof kit.
Follow the instructions and assembly steps in the assembly instructions.
The twin-wall sheets must not be walked on without crosswise running boards (over at least 2 rafters).
Point loads must be avoided at all costs.
Remove snow from the roof regularly. A snow height of more than 10 cm can already become dangerous (layer
heights of 36 cm for dry snow, 10 cm for watery snow and 5.5 cm for ice correspond to a weight of approx. 50 kg/
m²).
Snow load: models with 3-4 m roof depth: 150 kg/m² and models with 5 m roof depth: 100 kg/m².
Included fastening material is for solid masonry only. Separate fasteners must be used for insulation, hollow blocks,
etc.
Keep the gutter free of leaves, dirt and snow.
The
patio
roof
must
Foundation dimensions: length 40cm x width 40cm x depth 80cm.
Clean the twin-wall sheets with water and a mild detergent, do not use abrasives, acetone or solvents!
Defective or bent posts or beams must be replaced immediately.
The
wall
connection
upper edge of the profile).
3m depth: 240cm = 7° - 300cm = 20°
4m depth: 240cm = 5° - 340cm = 20°
As the cross beam can be moved by max. 60cm towards the house wall, this results in a higher roof pitch (slope).
Colour and size deviations etc. within the usual tolerances reserved. Our recommendations do not release the custo-
mer from the obligation to check the product on his own responsibility. In case of doubt, please consult a specialist.
Technical modifications reserved.
T
he Premium Terrace Roof has been developed and manufactured according to EN 1090. It may only be used for
roofing over a terrace with appropriate fastening for the respective house wall and for non-commercial use. Any use
other than the intended use described here is considered improper use. The manufacturer is not liable for any damage
or consequential damage resulting from improper, incorrect or inappropriate use.
4 und 5
notices
and
instructions.
be
mounted
on
profile
must
be
13, 17, 19
Failure
to
do
a
level,
solid
foundation
attached
at
the
following
17
TX 25
so
may
result
in
(e.g.
concrete,
concrete
height
(measured
Ø 12
GB
serious
slabs).
at
the
3
3

Publicité

loading

Ce manuel est également adapté pour:

429503742951214295137429503942950554295139 ... Afficher tout