11. BATTERY CHARGER CONTROLS
On/Off Switch
Use this switch to select between the Maintain/Charge rate,
Boost rate or the Engine Start mode.
OFF – When the switch is in this position (middle), the
charger is turned off.
Boost or Maintain/Charge – When the switch
is in this position, the Rate Selection button can be set to
either the 6A<>2A Maintain/Charge rate or the 40 amp Boost
setting.
Engine Start – When the switch is in this position, the
Engine Start LED will illuminate and the unit will be in the
200A Engine Start mode.
Digital Display
The Digital Display gives a digital indication of voltage or
amperage. It always starts in Voltage mode, but can be
switched to other mode by pressing the Display button as
shown below:
• Boost mode:
Voltage ˃ Amperes ˃ Voltage...
• Maintain/Charge mode:
Voltage ˃ Amperes ˃ OFF ˃ Voltage...
• Engine Start mode:
Voltage (No Amperes mode)
If the process is stopped on any mode (by pressing the
START/STOP button), the display will show "OFF".
NOTE: When in Maintain/Charge mode, the display will
automatically go into sleep mode (shut-off) after 2 minutes.
To turn the display back on, press any push-button.
EEBC100A-Z
All manuals and user guides at all-guides.com
Display Button
Use this button to set the function of the digital display to one
of the following:
A – The display shows the output current, in amps.
V – The display shows the battery voltage.
Start Stop Button
Use this button to start or stop the charging or boosting
process, after the battery is properly connected and an
output or Boost rate has been selected.
Rate Selection Button
When in Maintain/Charge mode, use this button to select one
of the following rates:
Boost 40A – For quickly adding energy to a severely
discharged or large capacity battery.
NOTE: We recommend using BOOST mode prior to ENGINE
START for several minutes.
Maintain/Charge 6A<>2A – For charging small and large
batteries. Not recommended for industrial applications.
LED Indicators
has detected that a battery is connected, and is performing
the selected operation – either Boost or Charge.
The charger is in abort mode.
is fully charged and the charger is in maintain mode.
are reversed.
NOTE: See OPERATING INSTRUCTIONS for a complete
description of the charger modes.
9
Boost/Charge (yellow/orange) LED lit: The charger
Boost/Charge (yellow/orange) LED flashing:
Maintaining/Charged (green) LED pulsing: The battery
Reversed (red) LED flashing: The connections

Publicité