RBC-1200-CA
FeAtuReS
Automatic Self-test
The machine will automatically perform a self-test when it is turned on. The count display will show 0 and the preset display
will show nothing. If there is a problem, the preset display will show an error code (See ERROR CODE DISPLAYS).
Automatic Start
The machine is programmed to automatically start counting bills once placed into the hopper.
Dimension Detection (DD)
The machine checks the width of the bills inserted. If there are bills that are different widths like foreign bills or bills stuck
together, the machine will stop allowing for removal of the bill. The DD indicator will turn on when this function is in use.
The DD button is used to turn on this function.
Common Counting
The machine will count all of the bills placed in the hopper.
Batch Counting
When the machine is in batch mode it will count batches between 1 and 999. The +1 and x10 buttons are used to
determine the batch size.
Accumulative Counting (ADD mode)
ADD mode is used to get an accumulative total of the bills counted. It will count the bills placed into the hopper and add that
amount to the next bills counted. The ADD mode indicator will turn on when this function is in use. The ADD button is used to
turn on this function.
Auto Reset
When using common and batch counting modes, the machine will automatically clear and reset the count display once the
counted bills on the stacker are removed and new bills are placed in the hopper.
7