3 Function of the device

3.1 Device Overview (ill. A)

1 Adaptor for high-pressure hose
2 Water inflow
3 Pressure control valve
4 Valves
5 Connecting hose pump - reel

3.2 Functional description

The high-pressure pipe cleaning devices are self-priming
compact devices for cleaning pipes, drains, downpipes,
house service connections, rain downpipes and for
cleaning work in ducts of the following diameters:
HD 13/100 -2 Ø40 – 150mm up to a maximum length
of 20 metres.
This model is fitted with:
1 Three ceramic plungers Ø18mm.
2 Pump with crankshaft system.
3 Brass headstock.
4 Induction motor and hollow shaft.
5 Continuously variable pressure regulation.
When using a washing lance the high-pressure cleaners
also serve to clean the surfaces of motor vehicles,
buildings, machines, etc.

3.3 Initial operation (ill. B)

!
Warning
The high-pressure cleaner must only be operated if all
information on the safety of people and the machine
is observed!
!
Warning
The machines must not be positioned and operated
in rooms subject to fire and explosion hazards or in
puddles. The devices must not be operated under
water!
OPERATING GUIDELINES
Water connection facilities (ill. 1):
Proceda de la siguiente manera:
1 Use the hose clamp to fasten the water hose to the
suction connection (A) on the pump.
!
Please note: only use clean water.
2 Connect the water hose to the water supply and
turn on the tap. The amount of water must be
adequate for the respective high-pressure cleaner
type.
When drawing water in from a water tank, fasten
the water intake hose (accessory item no.: 7.6066)
to the intake adaptor (A) on the pump by means of
the cap nut and insert the sieve (B) into the water
tank.
!
Never position the machine higher than the
tank!
!
Please note: do not draw in dirty water. Sieve
on the intake hose.
3 Plug the line cord plug into the socket
Please observe the necessary fuse protection in
accordance with the current consumption of
the devices. When using cable drums, be sure to
unwind the cable completely.
4 Avoid loops when unwinding the high-pressure
hose and nozzle and insert into the pipe to be
cleaned
When using a washing lance (accessory item no.:
7.6088) please connect this to the highpressure
hose by means of an adaptor.
!
In doing so, the high-pressure hose and nozzle
are to be in the pipe and only removed when
the device has been switched off.
The on/off switch serves simultaneously as the motor-
circuit switch and shuts down if the set value (ampere)
is exceeded.
Pipe cleaning nozzles are to be used depending on the
type of contamination.