VENTED COUNTERFLOW WALL FURNACES
FAW55SPPX - 2
FAW55SPPX-1, FAW551SPP Converted To PSE Pilot
This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other
qualified agency¹)* in accordance with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
National Fuel Gas Code Z223.1 (Latest Edition)
1
*The term "qualified agency" means any individual, firm, corporation or company which either
in person or through a representative is engaged in and is responsible for (a) the installation
of gas piping or (b) the connection, installation repair, or servicing of equipment, who is
experienced in such work, familiar with all precautions required, and has complied with all the
requirements of the authority having jurisdiction.
Perform the safety shutdown test any time work is done on a gas system to avoid the possibility
of fire or explosion with property damage, personal injury or loss of life.
CONTINUOUS IGNITION SYSTEMS
1. Place gas control knob in PILOT position. Main burner should go off and pilot should remain lit.
2. Extinguish pilot flame. Pilot gas flow should stop within 3 minutes. Safety shut-off of pilot gas proves complete shutdown
since safety shut-off valve blocks flow of gas to main burner and pilot.
3. Relight pilot burner and operate system through one complete cycle to make sure all controls
operate properly.
Part Description:
Pilot Orifice
Main Burner Orifice
Gas Valve
Conversion Label
45062-0-0523
INSTALLATION INSTRUCTIONS
GAS CONVERSION KIT 45060
FOR USE ON:
FOR CONVERSION TO NATURAL GAS
CHECK THE SAFETY SHUTDOWN PERFORMANCE
Empire Comfort Systems Inc. • Belleville, Illinois
DIRECT VENT COUNTERFLOW WALL FURNACES
DVC55SPPX-1, DVC551SPP Converted To PSE Pilot
WARNING
WARNING
PARTS LIST
Part Numbers:
R13442
P8842
R2148
R1322
DVC55SPPX - 2
Quantity Supplied:
1
2
1
1
Page 1

Publicité

loading

Sommaire des Matières pour Empire Comfort Systems 45060

  • Page 1 FOR CONVERSION TO NATURAL GAS WARNING This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other qualified agency¹)* in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage.
  • Page 2 12. Attach gas line to gas valve. 13. The converted furnace must be connected to a supply of the conversion gas and checked for leaks. 14. The furnace must be checked to ensure it is operating at the correct pressure of 4.0” w.c. The burner flame and pilot flame must also be checked for proper flame characteristics as outlined in Installa- tion Instructions and Owner’s Manual. Page 2 Empire Comfort Systems Inc. • Belleville, Illinois 45062-0-0523...
  • Page 3 DVC55SPPX-1, DVC551SPP Converti En Pilote PSE POUR LA CONVERSION EN GAZ NATUREL AVERTISSEMENT Cet ensemble de conversion doit être installé par un distributeur d’Empire Comfort Systems, Inc. (ou une autre agence qualifiée )* conformément selon les instructions du fabricant et selon tous les codes et exigences des autorités ayant juridiction. De sérieuses blessures ou des dommages à...
  • Page 4 10. Connecter le thermocouple et le tuyau de la veilleuse à la soupape de gaz. 11. Replacer et fixer l’ensemble complet du brûleur dans la chambre de combustion avec les vis que vous avez enlevées à l’étape 3. 12. Connecter la ligne de gaz à la soupape de gaz. 13. Le radiateur converti doit être branché à une alimenta- tion de gaz propre à la conversion et assurez-vous qu’il n’y ait aucune fuite. 14. Le radiateur doit être vérifié pour être certain qu’il fonc- tionne avec une pression de 4.0” w.c. Vous devez aussi vérifier la flamme du brûleur et de la veil- leuse pour s’assurer que les caractéristiques des flammes soient convenables comme il est indiqué dans Les Instruc- tions d’Installation et Manuel du Propriétaire. Page 4 Empire Comfort Systems Inc. • Belleville, Illinois 45062-0-0523...