Wire connector pins are bent.
Valve wiring is damaged.
symptom
Lights or blower
Control module switch in
won't function (if
wrong position.
equipped).
COM switch is unplugged.
Flames are very
Door is ajar.
aggressive.
Venting action is too great.
Appliance won't per-
No power to the system.
form any functions.
Receiver switch in wrong
position (if equipped).
Transmitter isn't operational.
symptom
The following applies specifi cally to the SIT system only:
Pilot will not light.
Ignition box has been locked
Makes no noise with
out.
no spark at pilot
burner. (Lights and
blower operate, if
equipped).
note:
Starting from off, press the on button on the transmitter. After approximately 4 seconds on/off button is pressed, the ignition
board will start the spark. The atempt for ignition will last approximately 60 seconds. If there is no fl ame ignition (rectifi cation),
the board will stop sparking and the board will go into lock out.
symptom
The following applies specifi cally to the Maxitrol system only:
Pilot lights.
Manual override knob is in the
No gas fl ow.
"MAN" position.
Valve is not functioning properly.
No spark after pilot
Minimal voltage from thermocou-
ignition. Valve turns off
ple or resistance in circuit ports
in one minute and does
(Parts include: "ON/OFF" switch,
not operate.
receiver, thermocurrent connec-
tions or temperature switches).
No pilot ignition
Switch is in "OFF" position on
(5 second continuous
the valve.
beep).
Wiring is loose.
Receiver (if equipped).
Wire connector pins are bent.
-
Straighten pins.
-
Replace valve.
problem
-
Verify ON/OFF switch is in the "I" position which denotes on.
-
Verify "COM" switch is plugged into the front of the control
module.
-
Ensure door is secured properly.
-
Check to ensure venting is properly sealed or restrict vent
exit with restrictor plate. (Not available in all appliances).
-
Check breaker to verify it's in the "on" position.
-
Verify that the 3 position switch on the receiver is in the
remote position (middle).
-
Check battery power and battery orientation.
problem
Choose one of the 3 methods below to reset the system.
1.
To reset ignition box when locked out. Turn off power supply
and remove batteries (if used) from the back up battery pack.
To reset the DFC Board when the board goes into a lock
2.
out condition and the LED is blinking 3 times using the
transmitter on/off button:
To reset the DFC Board when the board goes into a lock out
3.
condition and the LED is blinking 3 times by cycling fl ame:
problem
-
Turn the knob to the "ON" position.
-
Valve is on pilot fl ow. Turn to the high setting, double click the large
fl ame button on the remote.
-
Replace valve. Do not overtighten.
-
Measure the voltage, it should read a least 5mV. The spade
connector is on the outer surface beside the magnet nut. Verify with
manufacturer the drop time, after thermocouple is heated measure
the drop time.
-
Switch to "ON" position.
-
Ensure wiring is properly secured.
-
Reset program: hold reset button on receiver and wait for 2 beeps.
Release after second beep. Press small fl ame button on remote
within 20 seconds, you will hear an additional beep (this signals a
successful reset).
-
Replace receiver.
-
Straighten pins.
troubleshooting (electronic)
test solution
test solution
Step 1: Turn the system off by pressing the on/off
button to turn the system off.
Step 2: After approximately 2 seconds press the on/
off button on the transmitter again. The DFC Board will
reset and the ignition sequence will start again.
Step 1: In the manual fl ame control mode, use the down
arrow button to reduce the fl ame to off, indicated by the
word OFF displayed on the transmitter LCD screen.
Step 2: Wait approximately 2 seconds and press the up
arrow button, the ignition sequence will start.
test solution
EN
69
W415-2882 / A / 12.10.20