Installation Guide Lighting Fixture
Spotlight
MMP-100S/1H/1E/30B/Z2/2
1 3/8"
7 3/64"
35mm
179mm
Pan lock
Set screw(M3)
2 59/64"
2 13/16"
2 3/32"
1 13/32"
53.1mm
35.8mm
74.1mm
71.5mm
FOR USE WITH EUTRAC CORP, Series 230 or 233, TRACK SYSTEM ONLY.
EUTRAC lighting track is sold separately, and we do not provide the applicable lighting tracks.
This fixture is compatible with Eutrac 2-circuit track only. The fixture attaches to both the left and right circuit rails of the track.
Please ensure that only ONE power feed is supplied to the track.
Weight
Input voltage
1.8lbs,815g
120V
Input current
0.334A
Input wattage
39.9W
Rotate degrees
10°
Dimmer
DVSTV-XX(sold separately)
90°
Lens Filter options
Full-Diffuser Lens Filter MLA-100/DF01
Semi-Diffuser Lens Filter MLA-100/DS02
Full-Spread Lens Filter MLA-100/SF01
Tilt lock
Semi-Spread Lens Filter MLA-100/SS01
Set screw(M3)
Edge-Control Lens Filter MLA-100/EC02
Sharpener Lens MLA-100/SH01
(available only for narrow distribution)
Installation Guide
MMP-100S/1H/1E/30B/Z2/2
INSTRUCTIONS FOR INSTALLING AND OPERATING MMP-100S SERIES TRACK LED LUMINAIRES.
FOR USE WITH EUTRAC CORP, Series 230 or 233, TRACK SYSTEM ONLY.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
To install the fixture safely《 Read carefully and follow all the instructions in the guide 》
Read and understand these instructions before installing fixture.
This fixture is intended for installtion in accordance with the National Electrical Code and local regulations. To assure full compliance with
local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at
fuse box before proceeding.
Retain these instructions for maintainance reference.
Warning : Failure to install the fixture properly could result in personal injury.
Caution :
Failure to install the fixture properly could result in property damage.
Warning
The fixture is for indoor use only in general conditions.
Before
Can not be used following conditions (Causes of falling, electrocution and fire)
installation
●Inclined, uneven surface
●High humidity
●Outside
●On the floor
●Vibrated or shocked areas
●Areas get direct sunlight
Please contact if you are not able to judge whether installation
environment is suitable to the places or not.
Caution
Please follow the fixturesʼ indication or specification for the distance of irradiated area.
(Causes of change in shape, change in color of irradiated objects)
Warning
Only qualified person may work on electric wiring and equipment. (Cause of accidents)
For electric
wiring
Use alternating current. Please follow rating plate of fixtures for power supply frequency.
(Cause of electrification・fire) (50Hz ・60 Hz common use for ballasts and incandescent lamp fixtures)
Be sure power supply voltage is within ±6% mentioned in rating plate or the guide. (Causes of short life of lamps・electrification・fire)
Be sure all the wires and codes are not damaged. (Causes of falling・damage)
Warning
Please follow the fixturesʼ instruction or this guide to install the fixture and lamp. (Causes of falling・electrification・fire)
At lighting
fixture
Switch off the power when installing the lamp. (Causes of electrification)
installation
Do not touch the fixture when switch is on or just turn off the switch because of high temperature.
Do not put or cover the fixture by any cloths, papers, or insulators.(Causes of not lighting・fire)
Do not place any metallic or flammable objects. (Cause of electrification・fire・broken fixture)
Make sure to install all the parts of fixtures besides installation and mounting parts will not touch with any
objects both inside and outside of ceiling such as lighting track, etc. (Causes of falling・electrification・fire)
Do not dismount or remodel fixtures. (Cause of electrification・fire・falling・broken fixtures)
Do not operate with wet hands.
If you smell smoke, see smoke, or find anything unusual, please turn the switch off and ask construction
companies to repair. (Cause of electrification・fire)
Make sure the construction will not affect any fire prevention systems such as sprinkler by heat from the fixture.
Caution
(Causes for improper operation)
Lighting Fixture
: Prohibited
: Strict observance
Ceiling which canʼt hold the fixture weight
Do not install any luminaire
assembly closer than 6 in.
●On the wall
from any curtain or similar
●Places affected by wind or air-conditioner machine
combustibe material.
●Near fire
●Dusty areas, corrosive gas outbreaks areas
●Ambient temperature under 0℃ and over 35℃

Publicité

loading

Sommaire des Matières pour Modulex MMP-100S Serie

  • Page 1 Installation Guide Lighting Fixture Spotlight MMP-100S/1H/1E/30B/Z2/2 Lighting Fixture Weight Installation Guide 1 3/8" Input voltage 1.8lbs,815g 120V 7 3/64" 35mm 179mm Input current 0.334A Input wattage 39.9W Rotate degrees MMP-100S/1H/1E/30B/Z2/2 10° Dimmer DVSTV-XX(sold separately) 90° Pan lock Set screw(M3) INSTRUCTIONS FOR INSTALLING AND OPERATING MMP-100S SERIES TRACK LED LUMINAIRES. Lens Filter options FOR USE WITH EUTRAC CORP, Series 230 or 233, TRACK SYSTEM ONLY.
  • Page 2 Installation Guide Lighting Fixture To install ModuleX safety MMP-100S/1H/1E/30B/Z2/2 Installation Details Installation Diagram Installation Details Installation Diagram Caution Caution FOR USE WITH EUTRAC COR P, Series 230,233 TRACK SYSTEM ONLY. Attaching luminaire to track Optional parts installation Lighting track is sold separately.
  • Page 3 Guide d'installation Appareil d'éclairage MMP-100S/1H/1E/30B/Z2/2 Poids Guide d'installation Appareil d'éclairage 1.8lbs,815g Tension d'entrée 120V 1 3/8" 7 3/64" 35mm Courant d'entrée 0.334A 179mm Puissance d'entrée 39.9W degrés Rotation MMP-100S/1H/1E/30B/Z2/2 10° Variateur DVSTV-XX(vendu séparément) 90° Pan lock INSTRUCTIONS POUR L'INSTALLATION ET LE FONCTIONNEMENT DES LUMINAIRES LED SUR RAIL SÉRIE Set screw(M3) Option MMP-100S.UNIQUEMENT POUR UNE UTILISATION AVEC UN SYSTÈME DE RAIL EUTRAC CORP, Séries 230 ou 233.
  • Page 4 Guide d'installation Appareil d'éclairage Pour installer la sécurité ModuleX MMP-100S/1H/1E/30B/Z2/2 Détails de l'installation Schéma d'installation Avertissement Détails de l'installation Schéma d'installation Avertissement UNIQUEMENT POUR UNE UTILISATION AVEC UN FIXER LE LUMINAIRE AU RAIL. Installation de pièces en option SYSTÈME DE RAIL EUTRAC CORP, Séries 230,233.

Ce manuel est également adapté pour:

Mmp-100s/1h/1e/30b/z2/2