Installation distances
C890T / C890TG Style
Combustible roof
465
INSTALLATION AGAINST COMBUSTIBLE WALLS
Combustible wall
Permitted area for
combustible parts
of the building
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing
glass hearth plate this is 10 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
100
75
350
Combustible wall
350
582
The minimum distance in front of the
stove opening to combustible parts
of the building or interior decoration
!
must be at least 1,1 m.
A separate glass hearth
The dimension diagrams only show
plate (accessory)
the minimum permitted installation
increases the connection
distances for the stove. When con-
height to the chimney by
necting to a steel flue, also note the
10 mm.
safety distance requirements of the
flue. The safety distance between an
uninsulated flue and a combustible
part of the building should be at
365
least 450 mm.
183
A = height from floor to chimney
Ø150
B = height from floor to c/c chimney
C = height from floor to air inlet
46
D = height from floor to lower edge
E = minimum height to sloped ceiling
Air inlet Ø67
113
INSTALLATION AGAINST FIREWALLS
600
Fire-retardant wall of
brick or concrete
50
700
Fire-retardant wall of
brick or concrete
200**
432**
connection upwards
connection rear
of hatch
from the centre of the chimney