Télécharger Imprimer la page

Gessi 63225 Manuel D'installation page 14

Publicité

PRELIMINARI - PRE-INSTALLATION INFORMATION - PRÉALABLES - VORBEREITUNG -
PRELIMINARES - ПРЕДВАРИТЕЛЬНАЯ ПОДГОТОВКА - ΠΡΟΕΡΓΑΣΙΕΣ - 引言
B - SHOWER HEAD CONTROL UNIT
Install in the safety zone: Z1
Power: 24 W
Input: 12 V dc, 2 A (max)
Output:
1.
LED: RGB+WW IP67 12V dc potenza 5 W (max)
Service temperature: 0°C÷50°C
Protection: IP66
C - POWER SUPPLY (can be ordered as come optional)
Install in the safety zone: Z3
Input: 100-240 V ac, 0.59÷0.29 A, 50÷60 Hz
Output: 12 V dc, 2 A (max)
Standard: EN60950-1
Connection between B-C
Length max = 8 m
Poles = 2
Section = 20-22 AWG
Connection between A-B1
Length max (Supplied) = 5 m
A
GREEN WIRE
RED WIRE
BLACK WIRE
WHITE WIRE
BROWN WIRE
YELLOW WIRE
Connection between A-B2
Length max (Supplied) = 5 m
A
BLUE WIRE
PINK WIRE
GREEN WIRE
GREY WIRE
WHITE WIRE
GREY+WHITE WIRE
BROWN WIRE
NOTE:
- connection to a circuit breaker with tripping current no higher than 30mA is mandatory.
- on the "A-B1" and "A-B2" power supply cable, the ferrite (supplied) must be positioned near the
connector in order to comply with Electromagnetic Compatibility requirements.
DATA FOR THE ELECTRICAL SYSTEM
ELECTRICAL CONNECTIONS DATA
B1
Contact no. 1
Contact no. 2
Contact no. 3
Contact no. 4
Contact no. 5
Contact no. 7
B2
Contact no. 1
Contact no. 2
Contact no. 3
Contact no. 4
Contact no. 5
14
NOTES
Cold white LED
Warm white LED
Intermediate white LED