90515201 FS1802BNB wo depth
TOTAL LENGTH OF CORD
25 FT.
50 FT.
7.6 M
15.2 M
WIRE SIZE AWG
18
18
9. Use only the supplied charger when charging your tool. The use of any other
charger could damage the drill or create a hazardous condition.
10. Use only one charger when charging.
11. Do not attempt to open the charger. There are no customer serviceable parts
inside. Return to any authorized Black & Decker service center.
12. DO NOT incinerate the battery packs even if they are severely damaged or
completely worn out. The batteries can explode in a fire.
13. A small leakage of liquid from the battery cells may occur under extreme usage,
charging or temperature conditions. This does not indicate a failure. However, if the
outer seal is broken and this leakage gets on your skin:
a. Wash quickly with soap and water.
b. Neutralize with a mild acid such as lemon juice or vinegar.
c. If the battery liquid gets in your eyes, flush them with clean water for a minimum of
10 minutes and seek immediate medical attention. MEDICAL NOTE: The liquid is a
25-35% solution of potassium hydroxide.
Charging the Battery
THE BATTERIES IN YOUR POWER PACK ARE NOT FULLY CHARGED AT THE
FACTORY. BEFORE ATTEMPTING TO CHARGE THEM, THOROUGHLY READ ALL
OF THE SAFETY INSTRUCTIONS.
The charger is designed to use standard household 120 volt 60 Hz power. NOTE: Do
not charge by means of an engine generator or DC power source. Use only 120V
AC.
1. Plug the charger into any standard 120 Volt 60 Hz electrical outlet.
2. Slide the charger onto the battery pack as shown in Figure 1 and let it charge
initially for 9 hours. After the initial charge, under normal usage, your power pack
should be fully charged in 3 to 9 hours.
3. Remove pack from the charger and place in tool. NOTE: To remove the battery
from the saw, press down on the release button on the back of the battery (Figure
2) and pull out.
1
Important Charging Notes
1. Longest life and best performance can be obtained if the battery pack is charged
when the air temperature is between 65°F and 75°F (18°- 24°C). DO NOT charge
the battery pack in an air temperature below +40°F(+4.5°C), or above +105°F
(+40.5°C). This is important and will prevent serious damage to the battery pack.
2. The charger and battery pack may become warm to touch while charging. This is a
normal condition, and does not indicate a problem.
All manuals and user guides at all-guides.com
4/23/07
12:53 PM
RECOMMENDED MINIMUM WIRE SIZE
FOR EXTENSION CORDS
75 FT.
100 FT.
125 FT.
22.9 M
30.5 M
38.1 M
16
16
14
6
Page 6
150 FT.
175 FT.
45.7 M
53.3 M
14
12