Troubleshooting Chart
If you are experiencing a problem that is not listed in this chart, or have
checked all the possible cause listed and you are still experiencing the
problem, see your authorized dealer.
Problem
Engine will not start
Generator has no output
troubleshooting
Cause
1. Check if engine switch is off.
2. Fuel Tank empty.
3. Check to make sure generator is not
connected to an appliance.
4. Check spark plug for loose spark plug cap
5. Check spark plug for contamination.
6. Check engine oil level.
1. Check if the DC circuit breaker is turned off.
2. Check AC receptacle and DC terminals for
loose connection.
3. Check to see if engine starting was
attempted with appliances already
connected to generator.
Correction
1. Turn engine switch to the Choke position.
2. Fill tank making sure not to overfill.
3. If connected, turn off the power switch on
the connected appliance and unplug.
4. If loose, push spark plug cap back into place
5. Remove spark plug and clean electrode.
6. If engine oil level is low, add oil as per
instructions.
1. Depress or flip the circuit breaker into ON
position.
2. Secure connection if necessary.
3. Turn off switch on the appliance, and
disconnect cable from receptacle.
Reconnect after generator has been started
properly.
27